1. ISO Rating/Ambulance RateKalispell Fire/Ambulance Dept. 336 1 st Ave. East • P.O. Box 1997 Kalispell, MT 59903-1997 Report to: Mayor and City Council From: Ted Waggener, Fire Chief Chris Kukulski, City Manager Subject: ISO Draft Report Meeting Date: April, 24,00 r_ OC;--== Telephone 406-758-7764 Fax 406-758-7758 Background: The city contracted with Emergency Services Consulting Group for a pre -ISO evaluation. The draft report has been received and will be discussed at the Council Work Shop on April 24,00. Recommendation: It is recommended the City Council concentrate on three areas of the draft report and consider policy changes in these areas: Fire department dispatch, available on -duty personnel and fire department training. Fiscal Effects: Depends on council action. Alternatives: As suggested by the council. Attachments: Draft Report from Emergency Services Consulting Group. March 12, 2000 Mr. Ted Waggener, Fire Chief Kalispell F"fre Department 336 1A Avenue East Kalispell, MT 59903-1997 Dear Chief Waggener, Thank -you for giving me the opportunity to review the fire defenses of Kalispell as they apply to ISO. Many things have been accomplished under your leadership. Your are to be congratulated on your efforts. I am sure that your improvement efforts will lead to a lower insurance rate for the citizens of Kalispell. This report contains projections based on (a) the materials provided to me, (b.) the city's ability to improve and (c.) its indication that it wants to improve. A number of recommendations are contained within this report that (if followed) will result in an improve€ wA in youx insurance rating. If the city complies with the recommendations listed in this report your fire classification will drop to class 4 and will be close to a class 3. If I can be of assistance to you in this endeavor, please do not hesitate to call. Good Luck! Ifi Chief Ted Waggener Kalispell Fire Department 336 1't Ave. East Kalispell, MT 59903-1997 Dear Chief Waggener, Understanding that you have a planning session this week, I am forwarding you an action plan for ISO improvements for your department. Please be advised that this is not the draft report that will follow this week but it does contain vital information that you have requested. My calculations indicate that the fire department will be able to obtain a class 4 rating. The exact specifics will be contained within the draft report. Sincerely, Joe Lynch Action Flan For ISO Improvements • A decision needs to be made concerning your emergency dispatch. Currently fire calls are handled by tie city dispatch center and ambulance dispatch only is handled by the county dispatch center_ Neither dispatch center is providing a complete servicq to the fire department_ There is a plan to establish a closer working relationship among the various fire departments in Flathead County and the county dispatch has indicated their willingness to handle your fire traffic. The county dispatch already receives the 911 fire calls and transfers them to the city: however, the system does not have the one -button transfer feature required by the ISO schedule. On ambulance dispatches, the county dispatches the call and reties on the Kalispell Fire Department to provide radio service to the call. My recommendation is for the county 911 to handle all fire and EMS radio traffic for the Kalispell Fire Departmem The programming of the county's CAD dispatch computer program will need to be changed to allow computer data analysis. • The fire department needs to upgrade the radio equipment throughout the fire station in order to receive the county transmissions. If the county system is employed, all off - duty firefighters should carry radios or pagers equipped with the county frequency. • The fire department needs to use the intercom-telephow line existing between the county 911 center and the fire station for a "rip and run' secondary dispatch circuit. The county indicated that they could "dump" their dispatch screen to a remote printer. A dedicated dot matrix printer set up in the apparatus room or duty office would suffice. This would give you the two dispatch circuits that your department needs. Both circuits are required to be used on every call. • The city's 911 capability needs to be enhanced to receive one -button transfer from the county 911 center_ This would include anie and ally data. • The needed fire flow for the city is 3500 gallons per minute requiring three engine companies. You have three engine companies and one ladder. If your plans are to decommission the 1950 Pierch, you will not receive total reserve credit Two engine companies and one ladder should respond to each report of structure fire in the city. More information about the response will be included in the draft report. • All equipment listed on the ISO apparatus and equipment form should be on the appropriate truck Some of the equipment is for pumpers and the other equipment is for the ladder. • The 5 year non-destructive testing and the annual 400 pound cylinder drift test of the aerial ladder should be continued. • In considering the distribution of fire stations, the maps provided indicated 18,000 feet was the approximate extreme city limits. One fire station seems to take care of most of the city coverage area. I am concerned about the e=eme North section of the city around the Buffalo Stage! Riverview Green areas. The remote and limit access characteristics produce a lengthy response time. As the city grows, plans should be developed to establish a fire station in the northern area_ I understand that the barrier of the Stillwater River will not allow a contiguous area at the present: however, city planners should consider the possibility of connecting the two northern peninsulas of the city. For the present, the city should consider an automatic aid agreement with the Evergreen Fire Department specifically to enhance coverage in the Buffalo Stage/ Riverview Green areas. Forecasting growth for the community is beyond the scope of this study but (for ISO purposes) I would recommend that city plan the development of a second station along Hwy. 93 in the area of Grandview. This would create a 2 '/2 mile response to the the Buffalo Stage/ Riverview Green areas. • The city needs to strengthen the available on -duty personnel. For safety and ISO improvement, the on -duty force should never drop below four firefighters. A recall program should be established for the additional pumper and ladder service. This will be discussed in the draft report. • The department should begin reporting the total time out of service for the transport unit each month. The data should be separated between in and out of city responses. • The cry needs to establish a training center. I would encourage the city to explore the Creston Training Facility that is located approximately 7S miles away_ The city could claim this facil gas rtstraining center. Another sug•es6m-aoaldbefor the city to cAyAvec uic vvpnwntof its own training center. Usually, an -industrial area is better suited for this purpose. A minimum of two acres is required for this purpose. If the city acquires land for a second fire station, a training center could be located there. The fire station could be part of the two acres. • The city needs to establish a hydrant flow/ pressure check process in which ALL hydrants are flowed and tested at least once a year. Currently this is not being performed annually. The ISO schedule calls for this to be performed twice a year. I will discuss this in the draft report. • The department should have a designated training officer and water supply officer. These two postions are critical to the lowering of your insurance classification. Recommendations Receiving and Handling Alarms This grading feature reviews the alarm and communications systems of the fire department. Ten schedule points are available in this area.. 1. Item 414. Credit For Telephone Service Telephone service is based on the population served by the dispatch center. The city's dispatch center represents approximately 16,000 people while the county center represents 60,000 (U.S. Census-1990). If the fire department uses the city's current dispatch center, two emergency lines and one business line will be required. If the fire department chooses the county's 911 center, four emergency lines and two business lines will be required. Arrangements with the telephone company should be made so that these lines progress (rollover) to each other. These lines can be standard seven digit numbers or 911 lines. A policy.should be established to receive all autocnatic fire alarms calls on a specific seven digit alarm line. The telephone directory listings were consistent will the ISO Fire Suppression Grading Schedule. Each year, the published telephone directory should be reviewed to make sure that the face deparune # listings are present in the three areas -mandated by the schedule. I anticipate the department scoring 2.00 points in this area 2. Item 422. Credit For Operators The information provided to me indicates that 5,475 calls are handled by a staff of 1.3 dispatchers at the city dispatch center and 12,775 calls are handled by a staff of 2.41 dispatchers at the county dispatch center. Discussion were held during the site visit about the county's dispatch center involving the possibility of meeting the current NFPA 122I's performance -based criteria. The Under -Sheriff indicated that it was possible to program the CAD to produce this report. I would follow-up with that discussion and request that change. The standard calls for a performance indicator that compares the time that the 911 phone rings to the time the call is answered to the time the call is dispatched. The standard calls for 95% of all calls to be answered in 30 seconds and in no case shall a call take over 60 seconds to be answered. Once the call is answered, the dispatcher has another 60 seconds to dispatch the call. This has to be substantiated by computer analysis using the three variables mentioned before. In most cases, less personnel are required to meet the ISO standard by the performance -based criteria than by the activity count method. Law enforcement has not equalivant standard The activity count method is part of the previous NFPA 1221 standard (1988 edition) and it simply compares the activity level of the dispatchers to the staffing level. The activity level of the city's-dispatch-center requiestwo, around the clock dispatchers while the county's activity level requires three dispatchers. The county's dispatch center is not capable of producing the report that would indicate compliance with the performance -based criteria. Therefore, I calculated the points based on the activity count method. With this in mind, I anticipate the department scoring 1.30 points in this area. 3. Item 432. Credit For Dispatch Circuits The primary circuit for the fire department is radio. If the department chooses to change its fire dispatch to the county 911 center, a radio or radio monitor should be installed in the fire station with speakers throughout the building. Currently, a PA -telephone line connected to speakers throughout the fire station is connected to the county 911 center. I recommend that this line be used to "dump" the CAD screen of the county 911 center to a dot matrix "rip and run" printer to be used as a secondary circuit. Remember that this will require a programming change of the county's CAD system. Emergency power is not an issue at the city or the county dispatch centers. With this in mind, I anticipate the department scoring 5.00 points in this area. Fire Department The fire department feature addresses the various equipment, personnel, and training needs of the fire department. 4_ Item 513. Credit for Engine Companies Due to needed fire flow, the department is required to have three engine companies. The department has three engine companies. It is imperative that all equipment listed in table 512.A. of the Fire Suppression Grading Schedule should be on all three pumpers. Mahe sure that all hose is tested to at least 250 psi for 5 minutes and the pumps are tested annually to NFPA 1901 specifications. Two pumpers are required for response to all structural fires in the city. This should be included in a fire department SOP or SOG. Off -shift firefighters can be used for one of the pumpers: however, the response must be guaranteed. With this in mind, I anticipate the department scoring 10.00 points in this area. 4. Item 523. Credit for Reserve Pumpers With the arrival of the new Smeal pumper, the department plans to decommission 1950 Pierch pumper. Due to redundancy in existing engines, the department will score reserve pumper credit even though there is no reserve. With this in mind, I anticipate the department scoring 0.67 points in this area. 5. Item 532. Credit for Pump Capacity With the arrival of the new pumper and the decommissioning of the 1950 Pierch, the department will have 5,500 gallons of pump capacity. The needed fire flow for the city is 3,500 gallons. With this in mind, I anticipate the department scoring 5.00 points in this area. 6. Item 549. Credit for Ladder Service Due to the number of structures 35 feet or three stories in height, the is required to have an aerial ladder. The department currently have an aerial ladder. It is imperative that the department equip the ladder with all the equipment on table 544. A., and 544. B. of the Fire Suppression Grading Schedule. It is important that the department continue the non-destructive testing of the aerial ladder every five years and begin the NFPA cylinder drift test annually. The guideline for this in-house test are published in NFPA 1901. The aerial ladder must be responded to all reports of structure fire in the city to get the ISO credit. The response can be made by off -shift firefighters but it is important that the response is guaranteed. Response time is not as important as the assurance that the aerial ladder is assigned and used for all structural fires without delay! This should be in a fire department SOP or SOG. With this in mind, I anticipate the department scoring 5.00 points in this area 7. Item 56 1. Credit for Distribution The calculation Mused in 1994 was -used in- this study. A slight improvement is in this score is anticipated due to your compliance with the equipment mandates of the ISO schedule for pumpers and ladders. I do not anticipate a real improvement in this grade until a second station is established. The location of a second station is recommended in the area of Grandview Street in the northern part of the city. This will provide a quicker response to the Buffalo Stage/Riverview Green areas. The city matches its current response demands with fire department equipment: however, automatic aid with the Evergreen Fire Department should be considered for the Buffalo Stage/Riverview Green areas for response time considerations. With this in mind, I anticipate the department scoring 2.12 points in this area. 8. Item 571. Credit for Company Personnel The department has M firefighters on- staff (four shdl&of four firefighters with two relief personnel). The department maintains a minimum staff of three on -duty firefighters on duty. It is a concern that the fire department now responds two of the three on -duty firefighters to county ambulance calls and relies on off -shift personnel to fill in at the station. I have calculated the personnel credit on the basis of three on -duty and three off -shift personnel responding on foes. The department will continue to score low in the personnel In 1994, the department scored 2.43 points in personnel. In order to receive full credit in the grading schedule, six firefighters are required on each pumper and ladder truck. For safety reasons and the grading schedule, I believe that at least four firefighters should be on -duty at all times. This item should be improved along with the implementation of an aggressive recall program for off -shift firefighters. The department operates an ALS transport ambulance. The ISO schedule deducts personnel for EMS responsibilities. On non -transport agencies, the deduction is one firefighter for 2000 EMS calls. On transport agencies, the deduction is prorated as to the time a transport unit is out of service. The department does not currently calculate the time out of service for their transport unit. The calculations used in this report are based on one personnel being taken away due to the 2000 EMS calls. With this in mind, I anticipate the department scoring 1.88 points in this area. 9. Item 581. Credit for Training Training is an area in which the department can make significant gains. I will be forwarding you some forms for consideration in documenting your training program. The ISO schedule is- specific in the training hours that must be verified by records. The ISO field representative will want to review your training records by shift. The department should develop a training center that will include a drill tower of at least five stories in height along with a bum building. I will be happy to give you input on the design of these facilities. The department is entertaining the development of a regional training center. The Creston Training Center would benefit the department greatly. The county government should be solicited to assist in this endeavor. This would be a way in which the county government could help all fire departments by making a minimal investment. To determine the current grade, this report considered the department having a tape on fighting flammable liquid fires, a VCR, slide project, pump and hydrant cutaways, and a training area with water supply. All drills should be performed at the training facilities. A total of fourteen drills are required. The training officer should pre -schedule all drills and special category training to ensure compliance with the schedule. Any drill- center should be located on two- acres of property. The burn building should be able to withstand repetitive fires. Please contact me prior to the development of such facilities for input. Furthermore, I have calculated the training credit with the department in compliance with categories B. through H. of item 580. (Training) of the fire Suppression- Grading Schedule. Pre -fire plans should be completed on each commercial structure in the city and revisited on a bi-annual basis. With this in mind, I anticipate the department scoring 7.56 for this item. All the fire departments in Flathead County need training facilities. Why not share the expense and effort in establishing these facilities? A coalition approach is very desirous in creating a training facility. A committee should be established to determine the number of needed facilities and plan the development of such facilities The fire departments, county government, public utilities, and private corporations all befit from improved fire training. Building a coalition will lessen the cost of each facility and allow multiple facilities to be built. Also, by every fire department being involved, the county and state governments are more likely to provide funding or land for this project. The committee should inventory the training capabilities within the county first and develop cooperative agreements with those departs that have existing facilities, Exishng facilities should be improved to meet state and ISO requirements. Future training sites should be developed as funding is secured. Realistically, it will take up to five years to develop the number of training facilities that will be required in the county. Water Supply This feature evaluated the water supply available for fire protection. The department received a good- grade for the water supply in 1994 and (considering the improvements made), I anticipate they will receive at least the same grade in a future rating. The water department has improved the system since the last inspection and consequently, the available water has improved. All tanks are kept full. The city currently has the water capacity to provide the mwd m= daily d:onsumption. mwR of the required fire flow for three hours. That amount is 1,622,525 gallons of water. A water supply officer should be established to analyze all areas of the city to determine if insufficient water flow and hydrant distribution is present. This process is called a water supply inventory. Alternative water supply techniques should be employed to overcome challenges. The water supply officer should compare the water distribution system to the needed fire flows identified in the batch report. Ail new water mains in the county should be at least 6" in diameter. The ISO schedule mandates that at least 250 g.p.m. for two hours shall be maintained at representative locations in order to qualify for a class 8 rating or be -ow Pressurized hydrants, dry hydrants, and large diameter hose should all be considered in developing this water supply. A systematic approach to water supply should be undertaken to develop new water supply sources in each area identified as water supply challenged. The weight capacity of all bridges in Kalispell. should be determined to assist with the planning for possible tanker shuttle operations. The city should start testing and flowing fire hydrants at least once a year. The schedule calls for two such tests. The second test can be an "operational" test_ Please contact me concerning the second test. (If you do the things that I mentioned as the minimal in the report) GRADING ITEMS Actual Maximum 2.00 2.00 1. (Item 414.) Credit For Telephone Service 1.32 3.00 2. (Item 422.) Credit For Operators 5_ 00 5.00 3. (Item 432.) Credit For Dispatch Circuits 10.00 4. (Item 440.) TOTAL CREDIT FOR RECEIVING AND HANDLING ALARMS 10.00 10.00 5. (Item 513.) Credit For Engine Companies (7.5 if four are required) . 67 1.00 6. (Item 523.) Credit For Reserve Pumpers 5.00 5.00 7. (Item 532.) Credit For Pump Capacity 5.00 5.00 8. (Item 549.) Credit For Ladder Service 9 1.00 9. (Item 553.) Credit For Reserve Ladder Service 2.12 4.00 10. (Item 561.) Credit For Distribution 15.00+ 11. (Item 571.) Credit For Company Personnel 7.56 9.00 12. (Item 581.) Credit For Training 32.23 50.00+ 13. (Item 590.) TOTAL CREDIT FOR FIRE DEPARTMENT 32.06 35.00 14. (Item 616.) Credit For The Water System I •� 2.00 15. (Item 621.) Credit For Hydrants 1.39 3.00 16. (Item 631.) Credit For Inspection And 35.35 40.00 17. (Item 640.) TOTAL CREDIT FOR WATER SUPPLY 18. RECEIVING AND HANDLING FIRE ALARMS 8.30 FIRE DEPARTMENT WATER SUPPLY DIVERGENCE TOTAL CREDIT Classification Breakdown 90-100 Class One 80-89.9 Class Two 70-79.9 Class Three 60-69.9 Class Four 50-59.9 Class Five 40-49.9 Class Six 30-39.9 Class Seven 20-29.9 Class Eight 10-19.9 Class Nine 00-9.99 Class Ten 32.23 35.35 -4.79 71.09 Kalispell Fire/Ambulance Dept. 336 1 st Ave. East • P.O. Box 1997 Kalispell, MT 59903-1997 Report To: Kalispell Mayor and City Council From: Ted A. Waggener, Fire Chief Chris Kukulski, City Manager Subject: Rate increase request for Kalispell City Ambulance. Meeting Date: April 24, 2000 Background: The last rate increase for Kalispell City Ambulance was October 6 h, 1997, and was as listed below: Item Basic Life Support Disposables* Base Rate $235.00 Loaded Mile 6.00 (First 100) Over 100 4.35 Oxygen 25.00 First 1/2 hr.,$10.00 ea. additional hr. Drugs Advanced Life Support Disposables* $305.00 6.00 5.60 25.00 First 1/2 hr., 10.00 ea. additional hr. cost of drug Telephone 406-758-7764 Fax 406-758-7758 The proposed budget for 00-01 recommends supporting the general fund of the fire department by $99,145 from the ambulance fund. This was derived from 15% of all firefighters wages and 75 % of our E.M.S. Directors wages. This support of the fire department budget will allow us the two additional firefighters we are requesting in the that budget. This will help in our effort to lower our I.S. O. Rating. We are also recommending the hiring of a 1/2 time clerk H (the cost is $11,534.00) to help in ambulance billing and fire department secretarial duties. A 1/2 time clerk is needed as the work load has increased. Our ambulance runs are increasing each year, and the billing of Medicare, Medicaid and insurance is very time consuming. It would also provide the department with backup in case of illness etc. Recommendation: To approve a rate increase for the Kalispell City Ambulance, as listed below: Item Basic Life Support Advanced Life Support Disposables* Disposables* Base Rate $270.00 $370.00 Loaded Mile 7.00 7.00 (First 100) Over 100 4.35 5.60 Oxygen 30.00 First 1/2 30.00 First 1/2 hr.,$10.00 ea. hr., 10.00 ea. additional hr. additional hr. Drugs cost of drug Fiscal Effects: Increase in revenue of $112,523.00. Alternative: As suggested by the City Council. Attachments: See attachment #1 for comparison of rates throughout Montana. Respectfully Submitted, Ted Waggener Chris Kukulski Fire Chief City Manager v�����• N+�� WIWI MONTANA HEALTHCARE CONSULTANTS, INC. ALS BASE RATE BLS BASE RATE ALS MILEAGE BLS MILEAGE BLS ROUTINE SUPPLIES ALS ROUTINE SUPPLIES OXYGEN ALS IV SUPPLIES ALS INTUBATION SUPPLIES (406) 549-7104 1-800-850-4574 Fax (406) 542-2785 CHARGE RANGE FOR AMBULANCE RATES Pmse,07— KW —le— Pnpo-d Q4T{ $375.00 TO $450.00 A0370 306-00 3 70, 00 $250.00 TO $325.00 A0362 a a 7O .00 $7.00 TO $9.00 A0390 4.00 7• 0 0 $6.00 TO $7.00 A0380 6.00 7.00 $20.00 TO $25.00 A0382 $45.00 TO $60.00 A0398 $30.00 ' TO $45.00 A0422 30.0 O 36• O 0 $25.00 TO $40.00 A0934 $50.00 TO $80.00 A0396 Chief Waggener, Any price in this range is consistent with rates across the State of Montana. Call if you have any questions. 888 850-4574. 1008 Burlington Ave., Suite C • Missoula, Montana 59801