MDT/Chain Link Fence-LINE POST
TRUSS ROD
OF
36"
SECT1aN a LAWN 12" ROUND SECTION
3620 I 1 - ROUND
II SECTION FOR
CORNER
DOUBLE PANEL
PULL POST AND CORNER POST BRACING
END PULL PAST
END POST- STRETCHER BAR
FABRIC BAND -,
STRETCHER BAR
GATE
AREA
FABRIC
BAND
AS SPECIFIED
FABRIC BAND-,, iz--STRETCHER BAR
-----------------
L-CHAIN LINK FABRIC ji
B"
NOTE: TRUSS RODS -
NO CONCRETE BLOCK 12" ROUND SECTION —
REQUIRED FOR SINGLE
GATE. GATE LATCHES
DIRECTLY TO POST.
GATES
ANCHOR
LINE POST PULL
CHAIN LINK POST STRETCHER BAR ANCHOR LINE
FABRIC- \ TOP RAIL KNUCKLED SELVAGE /_POST
--TURNBUCKLE LTEN510N WIRE `-TURNBUCKLE "--TWISTED & IRON STRAP
12" ROUND SECTION IRON STRAP FABRIC BAND 5 BARBED SELVAGE
T
12" ROUND SECTION 12" ROUND SECTION _
CHAIN LINK FENCE - 3`. 4' & 5'
NOTES:
SEE THE STANDARD SPECIFICATIONS FOR FURTHER REOUIREMENTS.
DO NOT INSTALL DOUBLE PANELS MORE THAN 300' APART ON TANGENTS
OR MORE THAN 250' APART ON ANY CURVE. FOR CURVES SHARPER THAN
5' . INSTALL A DOUBLE PANEL ON EACH CURVE END. PLUS ONE ADDITIONAL
PANEL FOR EACH 10' OF DEFLECTION. EVENLY SPACED. BETWEEN THE
CURVE ENDS.
PULL POST BRACING ON 6 FOOT FENCE IS THE SAME AS CORNER BRACING.
A DROP BAR LOCKING DEVICE IS REQUIRED FOR ALL DOUBLE GATE INSTALLATIONS.
THE DROP BAR MUST BE ABLE TO BE INSERTED INTO THE CONCRETE BLOCK
AT LEAST SIX INCHES.
HEIGHT
OF FABRIC
WIRE FABRIC
ABOVE GROUND
DEPTH OF
CONCRETE
DEPTH OF POST
IN CONC. (FAN. 3
6'
1 "- 2"
36"
32"
5'
] "- 2"
36"
32"
4'
1 "-2"
"
30
26"
3"
1 "- 2"
30"
26"
ALL CONCRETE IS CLASS T" OR BETTER.
*HEN FENCE IS LESS THAN 50' FROM THE
EDGE OF A DRIVING LANE. USE A %' DIA.
GALVANIZED STEEL CABLE IN PLACE OF
THE TOP METAL BRACE RAIL.
DETAILED DRAWING
REFERENCE DWG. NO.
STANDARD SPEC. 607 - 2 5
SECTION 607
CHAIN LINK FENCE
EFFECTIVE: AUGUST 1996
�Gwr�rNA OEPARZACNT MONTANA
- - LF TRANSPO RTA 770V CARD