C_Trinity Lutheran Childcare Center_Site ReviewINDEX OF DRAWINGS
SHEET #SHEET TITLE
ABBREVIATIONS
A
AC ACRE
ADD ADDENDUM
ADA AMERICAN WITH DISABILITIES ACT
AB AS-BUILT
AHJ AGENCY HAVING JURISDICTION
B
BVCE BEGIN VERTICAL CURVE ELEVATION
BVCS BEGIN VERTICAL CURVE STATION
BTM BOTTOM
BLVD BOULEVARD
BLDG BUILDING
C
CATV CABLE TV
CL CENTER LINE
COK CITY OF KALISPELL
CJ CONSTRUCTION JOINT
CF CUBIC FEET
D
DEQ DEPARMENT OF ENVIRONMENTAL
QUALITY
DTL DETAIL
DIA DIAMETER
DIM DIMENSION
DIV DIVISION
DWG DRAWING
DR DRIVE
E
EW EACH WAY
E EAST
ELEC ELECTRIC
E CONTINUED
ELEV ELEVATION
EVCE END VERTICAL CURVE ELEVATION
EVCS END VERTICAL CURVE STATION
EQ EQUAL
EQUIP EQUIPMENT
EXIST EXISTING
F
FT FEET
FO FIBER OPTIC
FF FINISHED FLOOR
FEC FLATHEAD ELECTRIC CO-OP
FM FORCE MAIN
FJ FUSED JOINT
G
G GAS
GIS GEOGRAPHIC INFORMATION SYSTEM
H
HT HEIGHT
HWY HIGHWAY
HORIZ HORIZONTAL
HR HOUR
I
IN INCHES
ID INNER DIAMETER
IBC INTERNATIONAL BUILDING CODE
IE INVERT ELEVATION
J
JEA JACKOLA ENGINEERING AND
ARCHITECTURE
M
MH MANHOLE
MAX MAXIMUM
MIN MINIMUM
MT MONTANA
MPWSS MT PUBLIC WORKS STANDARD
SPECIFICATIONS
N
NEC NATIONAL ELECTRIC CODE
N NORTH
NWE NORTHWESTERN ENERGY
NIC NOT IN CONTRACT
NTS NOT TO SCALE
O
O.C.ON CENTER
O&M OPERATION AND MAINTENANCE
OPP OPPOSITE
OHP OVERHEAD POWER
P
PVI POINT OF VERTICAL INTERSECTION
PE PROFESSIONAL ENGINEER
PROP PROPERTY
PL PROPERTY LINE
Q
QTY QUANTITY
R
REF REFERENCE
REQ'D REQUIRED
REV REVISION
ROW RIGHT-OF-WAY
RD ROAD
LEGEND
TELEPHONE PEDESTAL
TRAFFIC SIGN
UTILITY POLE
WATER GATE VALVE
VEGETATION LINE
DECIDUOUS TREE
SEWER MANHOLE
CATCH BASIN
FIRE HYDRANT
STORM MANHOLE
SINGLE-PHASE TRANSFORMER
WATER METER PIT
WATER CURB STOP
WATER TEE
IRR IRRIGATION VALVE BOX
FROST FREE YARD HYDRANT
EXISTING BUILDING
EXISTING ASPHALT
EXISTING SIDEWALK
PROPOSED ASPHALT
PROPOSED BUILDING
PROPOSED SIDEWALK
CATCH CURB AND GUTTER
SPILL CURB AND GUTTER
DRIVE-OVER CURB AND GUTTER
CURB INLET
STORM DRAIN DRYWELL
fdc FIRE DEPARTMENT CONNECTION
SS
co CLEAN OUT
PIPE CAP
SD
DW
CB
EXISTING LIGHT POLE
T
E
C CABLE PEDESTAL
ELECTRICAL PEDESTAL
LIGHT POLE
GM GAS METER
W
CURB TRANSITION
J
THREE-PHASE TRANSFORMER
JUNCTION BOX
SECONDARY PEDESTAL
YD YARD DRAIN
CONIFEROUS TREE
SHRUB
1.ALL WORK IS TO BE PERFORMED IN ACCORDANCE WITH ALL GOVERNING CODES, ORDINANCES AND AUTHORITIES
HAVING JURISDICTION. GENERAL CONTRACTOR IS RESPONSIBLE FOR OBTAINING AND PAYING FOR ALL REQUIRED
PERMITS. THE GENERAL CONTRACTOR IS TO HAVE A FULL TIME QUALIFIED SUPERVISOR ON THE SITE AT ALL TIMES
WHILE WORK IS BEING PERFORMED.
2.ALL MATERIAL SPECIFIED IS TO BE NEW AND INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS
AND SPECIFICATIONS. GENERAL CONTRACTOR IS TO CONSTRUCT PROJECT IN ACCORDANCE WITH THE DOCUMENTS.
ANY DEVIATION FROM THE INTENT OF THE DOCUMENTS, WITHOUT ENGINEER'S APPROVAL, ARE AT THE
CONTRACTOR'S OWN RISK AND MAY RESULT IN THE WORK BEING DONE OVER AT CONTRACTOR'S EXPENSE
(MATERIALS AND LABOR).
3.CONTRACTOR TO REVIEW AND BECOME FAMILIAR WITH ALL EXISTING CONDITIONS PRIOR TO COMMENCING WORK.
ANY CONDITIONS NOT INDICATED ON CONTRACT DOCUMENTS ARE TO BE REPORTED TO THE ENGINEER PRIOR TO
BEGINNING WORK.
4.THE CONTRACTOR SHALL REMOVE ALL DEBRIS AS A RESULT OF THIS PROJECT. THE CONTRACTOR WILL REMOVE
EXISTING EQUIPMENT, FIXTURES, ETC. IN THE SPACE PRIOR TO CONSTRUCTION AND RELOCATE PER OWNER.
5.THE CONTRACTOR SHALL SCHEDULE HIS WORK AND MATERIAL AND EQUIPMENT DELIVERIES SO AS NOT TO
INTERFERE WITH THE DAILY VEHICLE TRAFFIC.
6.THE CONTRACTOR SHALL PROTECT EXISTING FACILITIES, EQUIPMENT, FIXTURES, ETC. FROM DAMAGE DURING THE
COURSE OF CONSTRUCTION.
7.ALL SURFACES AND/OR FINISHES DAMAGED AS A RESULT OF AND ADJACENT TO THE WORK SHALL BE REPAIRED AND
FINISHED TO EQUAL OR BETTER THAN ORIGINAL CONDITION.
8.ALL ITEMS REQUIRED BY THE DRAWINGS AND SPECIFICATIONS SHALL BE PERFORMED IN A WORKMANLIKE MANNER
BY PERSONS SKILLED IN THEIR RESPECTIVE TRADE AND WHO NORMALLY PARTICIPATE IN THE WORK OF THAT
TRADE.
9.THE ENGINEER SHALL BE IN THE FIRST INSTANCE THE SOLE INTERPRETER OF THE DRAWINGS AND SPECIFICATIONS
WITH REGARD TO THEIR MEANING OR INTENT.
10.CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES AND
PROCEDURES.
11.CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ASPECTS OF SAFETY AND TRAFFIC CONTROL DURING CONSTRUCTION.
12.CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING NECESSARY PERMITS INCLUDING, BUT NOT LIMITED TO,
SWPPP.
13.ALL WORK IS TO BE COMPLETED PER CITY OF KALISPELL AND MPWSS STANDARDS FOR DESIGN AND CONSTRUCTION.
REVISION DATEISSUE DATES
SS SANITARY SEWER
SCH SCHEDULE
SIM SIMILAR
S SOUTH
SPEC SPECIFICATION
SF SQUARE FEET
STD STANDARD
STA STATION
SD STORM DRAIN
SWPPP STORMWATER POLLUTION
PREVENTION PLAN
ST STREET
T
TEL TELEPHONE
TYP TYPICAL
TBD TO BE DETERMINED
TBC TOP BACK OF CURB
U
UP UNDERGROUND POWER
UT UNDERGROUND TELEPHONE
UNO UNLESS NOTED OTHERWISE
UTIL UTILITY
V
VERT VERTICAL
W
WTR WATER
W WEST
w/WITH
GENERAL NOTES
C-111 SITE & UTILITY PLAN
C-003 GENERAL CIVIL INFORMATION --/--/--
--/--/--
--/--/--
CD102 SITE DEMO PLAN
FENCE
UNDERGROUND POWER
WATER MAIN
UNDERGROUND TELEPHONE
OVERHEAD POWER
STORM DRAIN
SANITARY SEWER MAIN
EXISTING CONTOUR
DESIGN CONTOUR
EXISTING STORM DRAIN
EXISTING SANITARY SEWER
EXISTING UNDERGROUND PHONE
EXISTING WATER
EXISTING UNDERGROUND POWER
EXISTING GAS
EXISTING FIBER OPTIC
3030
3025
EXISTING OVERHEAD POWER
PROPERTY LINE
DRAINAGE SWALE / STORM POND
UNDERGROUND CABLE
GAS MAIN
EXISTING UNDERGROUND CABLE
UNDERGROUND FIBER OPTIC
ROOF DRAIN
PROPERTY EASEMENT
BUILDING SETBACK
IRRIGATION SLEEVE
FOUNDATION DRAIN
EXISTING PROPERTY LINE
VALLEY GUTTER
DATE:
KALISPELL
406-755-3208
#
BOZEMAN
406-586-0707
VANCOUVER
360-852-8746
DRAWN:CHECKED:
info@jackola.com jackola.com
PR
O
J
E
C
T
#
:
JACKOLA ENGR. & ARCH., P.C.
WITHOUT THE WRITTEN CONSENT OF
MAY NOT BE USED OR REPRODUCED
IS PROPRIETARY. THIS DOCUMENT
THE INFORMATION CONTAINED HEREIN
REVISIONS:
PRELIMINARY
NOT FOR CONSTRUCTION
CH
I
L
D
C
A
R
E
C
E
N
T
E
R
TR
I
N
I
T
Y
L
U
T
H
E
R
A
N
48
6
3
R
D
A
V
E
W
N
KA
L
I
S
P
E
L
L
,
M
T
BJL RAY
CIVIL TITLE
SHEET
C-003
C:
\
U
s
e
r
s
\
B
r
y
a
n
\
D
C
\
A
C
C
D
o
c
s
\
J
a
c
k
o
l
a
E
n
g
i
n
e
e
r
i
n
g
&
A
r
c
h
i
t
e
c
t
u
r
e
\
A
D
2
0
2
6
\
C
l
i
e
n
t
F
i
l
e
s
\
T
r
i
n
i
t
y
K
a
l
i
s
p
e
l
l
\
2
6
0
5
1
1
C
h
i
l
d
c
a
r
e
F
a
c
i
l
i
t
y
\
A
u
t
o
c
a
d
\
T
L
C
_
C
-
0
0
3
26
0
5
1
1
06/18/2026
SS
CB
CB
CB
GM
8
"
C
L
A
Y
1
0
"
P
V
C
1
0
"
P
V
C
1
0
"
P
V
C
2
1
"
R
C
P
XSSMH-01
XSDCB-04
XSDCB-05
XSDCB-06
FF: 2963.
0
3
'
FF: 2964.
6
2
'
FF: 2964.
7
2
'
FF: 2962.
9
0
'
FAILED AS
P
H
A
L
T
A
R
E
A
GAS LINE IN ALLEY
NOT MARKED AT
TIME OF SURVEY
3
R
D
A
V
E
W
N
/////////////////////////////////////
/
/
/
///////////////////////////////////////////////////////////////
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/////////////////
/
/
/
/
/
//////
/
/
/
/
/
/
/
/
/
//////
////////////
(W)
(W)
(W)
(W)
(W)
(W)
//////////////////////
(SS)
(SS)
(SS)
KEYNOTES:
1.NEATLY SAW CUT, REMOVE AND PROPERLY DISPOSE OF
ASPHALT.
2.NEATLY SAW CUT, REMOVE AND PROPERLY DISPOSE OF
CONCRETE.
3.DEMO BUILDING
4.CONTRACTOR TO LOCATE EXISTING SANITARY SEWER
CONNECTION AND REUSE.
5.CONTRACTOR TO LOCATE AND DEMOLISH WATER LINE
BACK TO WATER CURB STOP
6.REMOVE AND PROPERLY DISPOSE OF PLANTINGS, STUMP
AND ROOT BALL.
7.DEMO EXISTING GAS SERVICE.
REFERENCES
BUILDING REMOVAL
ASPHALT REMOVAL
CONCRETE REMOVAL
GRAVEL REMOVAL
UTILITIES REMOVAL
CURB AND GUTTER REMOVAL
//////
KALISPELL
406-755-3208
#
BOZEMAN
406-586-0707
VANCOUVER
360-852-8746
info@jackola.com jackola.com
REVISIONS:
DATE:
DRAWN:CHECKED:
THE INFORMATION CONTAINED HEREIN
IS PROPRIETARY. THIS DOCUMENT
MAY NOT BE USED OR REPRODUCED
WITHOUT THE WRITTEN CONSENT OF
JACKOLA ENGR. & ARCH., P.C.
PR
O
J
E
C
T
#
:
PRELIMINARY
NOT FOR CONSTRUCTION
CH
I
L
D
C
A
R
E
C
E
N
T
E
R
TR
I
N
I
T
Y
L
U
T
H
E
R
A
N
48
6
3
R
D
A
V
E
W
N
KA
L
I
S
P
E
L
L
,
M
T
SITE DEMO
PLAN
CD102
BJL RAY
06/18/2026
C:
\
U
s
e
r
s
\
B
r
y
a
n
\
D
C
\
A
C
C
D
o
c
s
\
J
a
c
k
o
l
a
E
n
g
i
n
e
e
r
i
n
g
&
A
r
c
h
i
t
e
c
t
u
r
e
\
A
D
2
0
2
6
\
C
l
i
e
n
t
F
i
l
e
s
\
T
r
i
n
i
t
y
K
a
l
i
s
p
e
l
l
\
2
6
0
5
1
1
C
h
i
l
d
c
a
r
e
F
a
c
i
l
i
t
y
\
A
u
t
o
c
a
d
\
T
L
C
_
C
D
1
0
2
26
0
5
1
1
SITE DEMO PLAN1 5-5 10 20
SCALE:
0
1" = 10'
1" = 10'
SS
CB
CB
CB
GM
8
"
C
L
A
Y
1
0
"
P
V
C
1
0
"
P
V
C
1
0
"
P
V
C
2
1
"
R
C
P
XSSMH-01
XSDCB-04
XSDCB-05
XSDCB-06
GAS LINE IN ALLEY
NOT MARKED AT
TIME OF SURVEY
3
R
D
A
V
E
W
N
X
X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
XXXXXXXXXXXXXXX
X
X
W W W W W
co
W
G
GM
10.00'
SETBACK
5.
0
0
'
SE
T
B
A
C
K
5.00'
5.
0
0
'
5.00'
5.
0
0
'
5.
0
0
'
SE
T
B
A
C
K
15.00'
SETBACK
17
.
3
0
'
13
.
2
7
'
14.80'
35
.
0
0
°
'
10
.
0
0
'
5.
1
3
'
SITE SUMMARY:
LOT SIZE: 0.172 ACRES
ZONE: R-3 RESIDENTIAL
BUILDING SETBACKS PER HOA AGREEMENT
FRONT - 15 FT
SIDE - 5 FT
SIDE CORNER -15 FT
REAR - 10 FT
MAX BUILDING HEIGHT - 35'
PARKING SUMMARY:
PROJECT LOCATED IN CITY OF KALISPELL PARKING DISTRICT #1
DISTRICT 1 REDUCES PARKING REQUIREMENTS BY 50%
DAYCARE CENTER= 1 SPACE PER EMPLOYEE AND 1 SPACE PER 6
STUDENTS
8 EMPLOYEES * 1 SPACE EACH + 44 CHILDREN * 1 SPACE PER 6
CHILDREN = 16 SPACES
SPACES REDUCED BY 50% PER PARKING DISTRICT #1 = 8 SPACES
REQUIRED
PARKING PROVIDED: BY SHARED PARKING WITH THE REST OF
CAMPUS
ADA PARKING REQUIRED - 1 STALL
ADA PARKING PROVIDED - 1 STALL
LANDSCAPING SUMMARY:
PERMITTED LOT COVERAGE = 45%
LOT SIZE: 7499.63 SF
LOT COVERAGE: 3370 SF
PROPOSED LOT COVERAGE: 44.93%
FENCE HEIGHTS:
FRONT - 4 FT
SIDE - 6.5 FT
SIDE CORNER -6.5 FT
REAR - 6.5 FT
KEYNOTES:
1.ASPHALT SECTION PER DTL.
2.STRIPING PER DTL.
3.THICKENED EDGE SIDEWALK PER DTL.
4.ADA RAMP PER DLT.
5.ADA SIGN PER DTL.
6.FENCE PER DTL.
7.CONTRACTOR TO LOCATE AND CONNECT TO EXISTING
SANITARY SEWER CONNECTION.
8.1" WATER SERVICE REPLACED FROM CURB STOP TO NEW
BUILDING.
9.NEW COMMUNICATIONS SERVICE PER ELECTRICAL PLANS.
10.ELECTRICAL TRANSFORMER AND VAULT, SEE ELECTRICAL
PLANS.
11.UNDERGROUND ELECTRICAL CONDUIT, SEE ELECTRICAL PLANS
FOR SIZE AND QUANTITY.
12.INSTALL NEW GAS SERVICE, COORDINATE WITH
NORTHWESTERN ENERGY
ASPHALT SECTION
#
KALISPELL
406-755-3208
#
BOZEMAN
406-586-0707
VANCOUVER
360-852-8746
info@jackola.com jackola.com
REVISIONS:
DATE:
DRAWN:CHECKED:
THE INFORMATION CONTAINED HEREIN
IS PROPRIETARY. THIS DOCUMENT
MAY NOT BE USED OR REPRODUCED
WITHOUT THE WRITTEN CONSENT OF
JACKOLA ENGR. & ARCH., P.C.
PR
O
J
E
C
T
#
:
PRELIMINARY
NOT FOR CONSTRUCTION
CH
I
L
D
C
A
R
E
C
E
N
T
E
R
TR
I
N
I
T
Y
L
U
T
H
E
R
A
N
48
6
3
R
D
A
V
E
W
N
KA
L
I
S
P
E
L
L
,
M
T
SITE & UTILITY
PLAN
C-111
BJL RAY
06/18/2026
C:
\
U
s
e
r
s
\
B
r
y
a
n
\
D
C
\
A
C
C
D
o
c
s
\
J
a
c
k
o
l
a
E
n
g
i
n
e
e
r
i
n
g
&
A
r
c
h
i
t
e
c
t
u
r
e
\
A
D
2
0
2
6
\
C
l
i
e
n
t
F
i
l
e
s
\
T
r
i
n
i
t
y
K
a
l
i
s
p
e
l
l
\
2
6
0
5
1
1
C
h
i
l
d
c
a
r
e
F
a
c
i
l
i
t
y
\
A
u
t
o
c
a
d
\
T
L
C
_
C
-
1
1
1
26
0
5
1
1
SITE & UTILITY PLAN1 5-5 10 20
SCALE:
0
1" = 10'
1" = 10'