Loading...
C_Trinity Lutheran Childcare Center_Site ReviewINDEX OF DRAWINGS SHEET #SHEET TITLE ABBREVIATIONS A AC ACRE ADD ADDENDUM ADA AMERICAN WITH DISABILITIES ACT AB AS-BUILT AHJ AGENCY HAVING JURISDICTION B BVCE BEGIN VERTICAL CURVE ELEVATION BVCS BEGIN VERTICAL CURVE STATION BTM BOTTOM BLVD BOULEVARD BLDG BUILDING C CATV CABLE TV CL CENTER LINE COK CITY OF KALISPELL CJ CONSTRUCTION JOINT CF CUBIC FEET D DEQ DEPARMENT OF ENVIRONMENTAL QUALITY DTL DETAIL DIA DIAMETER DIM DIMENSION DIV DIVISION DWG DRAWING DR DRIVE E EW EACH WAY E EAST ELEC ELECTRIC E CONTINUED ELEV ELEVATION EVCE END VERTICAL CURVE ELEVATION EVCS END VERTICAL CURVE STATION EQ EQUAL EQUIP EQUIPMENT EXIST EXISTING F FT FEET FO FIBER OPTIC FF FINISHED FLOOR FEC FLATHEAD ELECTRIC CO-OP FM FORCE MAIN FJ FUSED JOINT G G GAS GIS GEOGRAPHIC INFORMATION SYSTEM H HT HEIGHT HWY HIGHWAY HORIZ HORIZONTAL HR HOUR I IN INCHES ID INNER DIAMETER IBC INTERNATIONAL BUILDING CODE IE INVERT ELEVATION J JEA JACKOLA ENGINEERING AND ARCHITECTURE M MH MANHOLE MAX MAXIMUM MIN MINIMUM MT MONTANA MPWSS MT PUBLIC WORKS STANDARD SPECIFICATIONS N NEC NATIONAL ELECTRIC CODE N NORTH NWE NORTHWESTERN ENERGY NIC NOT IN CONTRACT NTS NOT TO SCALE O O.C.ON CENTER O&M OPERATION AND MAINTENANCE OPP OPPOSITE OHP OVERHEAD POWER P PVI POINT OF VERTICAL INTERSECTION PE PROFESSIONAL ENGINEER PROP PROPERTY PL PROPERTY LINE Q QTY QUANTITY R REF REFERENCE REQ'D REQUIRED REV REVISION ROW RIGHT-OF-WAY RD ROAD LEGEND TELEPHONE PEDESTAL TRAFFIC SIGN UTILITY POLE WATER GATE VALVE VEGETATION LINE DECIDUOUS TREE SEWER MANHOLE CATCH BASIN FIRE HYDRANT STORM MANHOLE SINGLE-PHASE TRANSFORMER WATER METER PIT WATER CURB STOP WATER TEE IRR IRRIGATION VALVE BOX FROST FREE YARD HYDRANT EXISTING BUILDING EXISTING ASPHALT EXISTING SIDEWALK PROPOSED ASPHALT PROPOSED BUILDING PROPOSED SIDEWALK CATCH CURB AND GUTTER SPILL CURB AND GUTTER DRIVE-OVER CURB AND GUTTER CURB INLET STORM DRAIN DRYWELL fdc FIRE DEPARTMENT CONNECTION SS co CLEAN OUT PIPE CAP SD DW CB EXISTING LIGHT POLE T E C CABLE PEDESTAL ELECTRICAL PEDESTAL LIGHT POLE GM GAS METER W CURB TRANSITION J THREE-PHASE TRANSFORMER JUNCTION BOX SECONDARY PEDESTAL YD YARD DRAIN CONIFEROUS TREE SHRUB 1.ALL WORK IS TO BE PERFORMED IN ACCORDANCE WITH ALL GOVERNING CODES, ORDINANCES AND AUTHORITIES HAVING JURISDICTION. GENERAL CONTRACTOR IS RESPONSIBLE FOR OBTAINING AND PAYING FOR ALL REQUIRED PERMITS. THE GENERAL CONTRACTOR IS TO HAVE A FULL TIME QUALIFIED SUPERVISOR ON THE SITE AT ALL TIMES WHILE WORK IS BEING PERFORMED. 2.ALL MATERIAL SPECIFIED IS TO BE NEW AND INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND SPECIFICATIONS. GENERAL CONTRACTOR IS TO CONSTRUCT PROJECT IN ACCORDANCE WITH THE DOCUMENTS. ANY DEVIATION FROM THE INTENT OF THE DOCUMENTS, WITHOUT ENGINEER'S APPROVAL, ARE AT THE CONTRACTOR'S OWN RISK AND MAY RESULT IN THE WORK BEING DONE OVER AT CONTRACTOR'S EXPENSE (MATERIALS AND LABOR). 3.CONTRACTOR TO REVIEW AND BECOME FAMILIAR WITH ALL EXISTING CONDITIONS PRIOR TO COMMENCING WORK. ANY CONDITIONS NOT INDICATED ON CONTRACT DOCUMENTS ARE TO BE REPORTED TO THE ENGINEER PRIOR TO BEGINNING WORK. 4.THE CONTRACTOR SHALL REMOVE ALL DEBRIS AS A RESULT OF THIS PROJECT. THE CONTRACTOR WILL REMOVE EXISTING EQUIPMENT, FIXTURES, ETC. IN THE SPACE PRIOR TO CONSTRUCTION AND RELOCATE PER OWNER. 5.THE CONTRACTOR SHALL SCHEDULE HIS WORK AND MATERIAL AND EQUIPMENT DELIVERIES SO AS NOT TO INTERFERE WITH THE DAILY VEHICLE TRAFFIC. 6.THE CONTRACTOR SHALL PROTECT EXISTING FACILITIES, EQUIPMENT, FIXTURES, ETC. FROM DAMAGE DURING THE COURSE OF CONSTRUCTION. 7.ALL SURFACES AND/OR FINISHES DAMAGED AS A RESULT OF AND ADJACENT TO THE WORK SHALL BE REPAIRED AND FINISHED TO EQUAL OR BETTER THAN ORIGINAL CONDITION. 8.ALL ITEMS REQUIRED BY THE DRAWINGS AND SPECIFICATIONS SHALL BE PERFORMED IN A WORKMANLIKE MANNER BY PERSONS SKILLED IN THEIR RESPECTIVE TRADE AND WHO NORMALLY PARTICIPATE IN THE WORK OF THAT TRADE. 9.THE ENGINEER SHALL BE IN THE FIRST INSTANCE THE SOLE INTERPRETER OF THE DRAWINGS AND SPECIFICATIONS WITH REGARD TO THEIR MEANING OR INTENT. 10.CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES AND PROCEDURES. 11.CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ASPECTS OF SAFETY AND TRAFFIC CONTROL DURING CONSTRUCTION. 12.CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING NECESSARY PERMITS INCLUDING, BUT NOT LIMITED TO, SWPPP. 13.ALL WORK IS TO BE COMPLETED PER CITY OF KALISPELL AND MPWSS STANDARDS FOR DESIGN AND CONSTRUCTION. REVISION DATEISSUE DATES SS SANITARY SEWER SCH SCHEDULE SIM SIMILAR S SOUTH SPEC SPECIFICATION SF SQUARE FEET STD STANDARD STA STATION SD STORM DRAIN SWPPP STORMWATER POLLUTION PREVENTION PLAN ST STREET T TEL TELEPHONE TYP TYPICAL TBD TO BE DETERMINED TBC TOP BACK OF CURB U UP UNDERGROUND POWER UT UNDERGROUND TELEPHONE UNO UNLESS NOTED OTHERWISE UTIL UTILITY V VERT VERTICAL W WTR WATER W WEST w/WITH GENERAL NOTES C-111 SITE & UTILITY PLAN C-003 GENERAL CIVIL INFORMATION --/--/-- --/--/-- --/--/-- CD102 SITE DEMO PLAN FENCE UNDERGROUND POWER WATER MAIN UNDERGROUND TELEPHONE OVERHEAD POWER STORM DRAIN SANITARY SEWER MAIN EXISTING CONTOUR DESIGN CONTOUR EXISTING STORM DRAIN EXISTING SANITARY SEWER EXISTING UNDERGROUND PHONE EXISTING WATER EXISTING UNDERGROUND POWER EXISTING GAS EXISTING FIBER OPTIC 3030 3025 EXISTING OVERHEAD POWER PROPERTY LINE DRAINAGE SWALE / STORM POND UNDERGROUND CABLE GAS MAIN EXISTING UNDERGROUND CABLE UNDERGROUND FIBER OPTIC ROOF DRAIN PROPERTY EASEMENT BUILDING SETBACK IRRIGATION SLEEVE FOUNDATION DRAIN EXISTING PROPERTY LINE VALLEY GUTTER DATE: KALISPELL 406-755-3208 # BOZEMAN 406-586-0707 VANCOUVER 360-852-8746 DRAWN:CHECKED: info@jackola.com jackola.com PR O J E C T # : JACKOLA ENGR. & ARCH., P.C. WITHOUT THE WRITTEN CONSENT OF MAY NOT BE USED OR REPRODUCED IS PROPRIETARY. THIS DOCUMENT THE INFORMATION CONTAINED HEREIN REVISIONS: PRELIMINARY NOT FOR CONSTRUCTION CH I L D C A R E C E N T E R TR I N I T Y L U T H E R A N 48 6 3 R D A V E W N KA L I S P E L L , M T BJL RAY CIVIL TITLE SHEET C-003 C: \ U s e r s \ B r y a n \ D C \ A C C D o c s \ J a c k o l a E n g i n e e r i n g & A r c h i t e c t u r e \ A D 2 0 2 6 \ C l i e n t F i l e s \ T r i n i t y K a l i s p e l l \ 2 6 0 5 1 1 C h i l d c a r e F a c i l i t y \ A u t o c a d \ T L C _ C - 0 0 3 26 0 5 1 1 06/18/2026 SS CB CB CB GM 8 " C L A Y 1 0 " P V C 1 0 " P V C 1 0 " P V C 2 1 " R C P XSSMH-01 XSDCB-04 XSDCB-05 XSDCB-06 FF: 2963. 0 3 ' FF: 2964. 6 2 ' FF: 2964. 7 2 ' FF: 2962. 9 0 ' FAILED AS P H A L T A R E A GAS LINE IN ALLEY NOT MARKED AT TIME OF SURVEY 3 R D A V E W N ///////////////////////////////////// / / / /////////////////////////////////////////////////////////////// / / / / / / / / / / / / / / / / / / / / / / / / / / ///////////////// / / / / / ////// / / / / / / / / / ////// //////////// (W) (W) (W) (W) (W) (W) ////////////////////// (SS) (SS) (SS) KEYNOTES: 1.NEATLY SAW CUT, REMOVE AND PROPERLY DISPOSE OF ASPHALT. 2.NEATLY SAW CUT, REMOVE AND PROPERLY DISPOSE OF CONCRETE. 3.DEMO BUILDING 4.CONTRACTOR TO LOCATE EXISTING SANITARY SEWER CONNECTION AND REUSE. 5.CONTRACTOR TO LOCATE AND DEMOLISH WATER LINE BACK TO WATER CURB STOP 6.REMOVE AND PROPERLY DISPOSE OF PLANTINGS, STUMP AND ROOT BALL. 7.DEMO EXISTING GAS SERVICE. REFERENCES BUILDING REMOVAL ASPHALT REMOVAL CONCRETE REMOVAL GRAVEL REMOVAL UTILITIES REMOVAL CURB AND GUTTER REMOVAL ////// KALISPELL 406-755-3208 # BOZEMAN 406-586-0707 VANCOUVER 360-852-8746 info@jackola.com jackola.com REVISIONS: DATE: DRAWN:CHECKED: THE INFORMATION CONTAINED HEREIN IS PROPRIETARY. THIS DOCUMENT MAY NOT BE USED OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF JACKOLA ENGR. & ARCH., P.C. PR O J E C T # : PRELIMINARY NOT FOR CONSTRUCTION CH I L D C A R E C E N T E R TR I N I T Y L U T H E R A N 48 6 3 R D A V E W N KA L I S P E L L , M T SITE DEMO PLAN CD102 BJL RAY 06/18/2026 C: \ U s e r s \ B r y a n \ D C \ A C C D o c s \ J a c k o l a E n g i n e e r i n g & A r c h i t e c t u r e \ A D 2 0 2 6 \ C l i e n t F i l e s \ T r i n i t y K a l i s p e l l \ 2 6 0 5 1 1 C h i l d c a r e F a c i l i t y \ A u t o c a d \ T L C _ C D 1 0 2 26 0 5 1 1 SITE DEMO PLAN1 5-5 10 20 SCALE: 0 1" = 10' 1" = 10' SS CB CB CB GM 8 " C L A Y 1 0 " P V C 1 0 " P V C 1 0 " P V C 2 1 " R C P XSSMH-01 XSDCB-04 XSDCB-05 XSDCB-06 GAS LINE IN ALLEY NOT MARKED AT TIME OF SURVEY 3 R D A V E W N X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X XXXXXXXXXXXXXXX X X W W W W W co W G GM 10.00' SETBACK 5. 0 0 ' SE T B A C K 5.00' 5. 0 0 ' 5.00' 5. 0 0 ' 5. 0 0 ' SE T B A C K 15.00' SETBACK 17 . 3 0 ' 13 . 2 7 ' 14.80' 35 . 0 0 ° ' 10 . 0 0 ' 5. 1 3 ' SITE SUMMARY: LOT SIZE: 0.172 ACRES ZONE: R-3 RESIDENTIAL BUILDING SETBACKS PER HOA AGREEMENT FRONT - 15 FT SIDE - 5 FT SIDE CORNER -15 FT REAR - 10 FT MAX BUILDING HEIGHT - 35' PARKING SUMMARY: PROJECT LOCATED IN CITY OF KALISPELL PARKING DISTRICT #1 DISTRICT 1 REDUCES PARKING REQUIREMENTS BY 50% DAYCARE CENTER= 1 SPACE PER EMPLOYEE AND 1 SPACE PER 6 STUDENTS 8 EMPLOYEES * 1 SPACE EACH + 44 CHILDREN * 1 SPACE PER 6 CHILDREN = 16 SPACES SPACES REDUCED BY 50% PER PARKING DISTRICT #1 = 8 SPACES REQUIRED PARKING PROVIDED: BY SHARED PARKING WITH THE REST OF CAMPUS ADA PARKING REQUIRED - 1 STALL ADA PARKING PROVIDED - 1 STALL LANDSCAPING SUMMARY: PERMITTED LOT COVERAGE = 45% LOT SIZE: 7499.63 SF LOT COVERAGE: 3370 SF PROPOSED LOT COVERAGE: 44.93% FENCE HEIGHTS: FRONT - 4 FT SIDE - 6.5 FT SIDE CORNER -6.5 FT REAR - 6.5 FT KEYNOTES: 1.ASPHALT SECTION PER DTL. 2.STRIPING PER DTL. 3.THICKENED EDGE SIDEWALK PER DTL. 4.ADA RAMP PER DLT. 5.ADA SIGN PER DTL. 6.FENCE PER DTL. 7.CONTRACTOR TO LOCATE AND CONNECT TO EXISTING SANITARY SEWER CONNECTION. 8.1" WATER SERVICE REPLACED FROM CURB STOP TO NEW BUILDING. 9.NEW COMMUNICATIONS SERVICE PER ELECTRICAL PLANS. 10.ELECTRICAL TRANSFORMER AND VAULT, SEE ELECTRICAL PLANS. 11.UNDERGROUND ELECTRICAL CONDUIT, SEE ELECTRICAL PLANS FOR SIZE AND QUANTITY. 12.INSTALL NEW GAS SERVICE, COORDINATE WITH NORTHWESTERN ENERGY ASPHALT SECTION # KALISPELL 406-755-3208 # BOZEMAN 406-586-0707 VANCOUVER 360-852-8746 info@jackola.com jackola.com REVISIONS: DATE: DRAWN:CHECKED: THE INFORMATION CONTAINED HEREIN IS PROPRIETARY. THIS DOCUMENT MAY NOT BE USED OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF JACKOLA ENGR. & ARCH., P.C. PR O J E C T # : PRELIMINARY NOT FOR CONSTRUCTION CH I L D C A R E C E N T E R TR I N I T Y L U T H E R A N 48 6 3 R D A V E W N KA L I S P E L L , M T SITE & UTILITY PLAN C-111 BJL RAY 06/18/2026 C: \ U s e r s \ B r y a n \ D C \ A C C D o c s \ J a c k o l a E n g i n e e r i n g & A r c h i t e c t u r e \ A D 2 0 2 6 \ C l i e n t F i l e s \ T r i n i t y K a l i s p e l l \ 2 6 0 5 1 1 C h i l d c a r e F a c i l i t y \ A u t o c a d \ T L C _ C - 1 1 1 26 0 5 1 1 SITE & UTILITY PLAN1 5-5 10 20 SCALE: 0 1" = 10' 1" = 10'