Loading...
Freddy's Frozen CustardTHRUDRIVE - - - - - - - - - - STAMP H:\ F \ F r e d d y s F r o z e n C u s t a r d \ M P G - M o n t a n a P r o p e r t y G r o u p - F r e d d y s \ M T . K a l i s p e l l - M P G - 0 0 0 0 0 1 . 3 0 - F r e d d y s - G r o u n d u p \ 0 C I V \ 2 - P l a n \ M G P 0 0 1 _ C 1 . 0 - S i t e . d w g - Ky l i e B a i l e y - 1/6 / 2 0 2 5 Init.#Issue / DescriptionDate PU B L I C I M P R O V E M E N T C O N S T R U C T I O N P L A N S FR E D D Y ' S F R O Z E N C U S T A R D LO T 6 , B L O C K 1 O F T H E K A L I S P E L L N O R T H TO W N S U B D I V I S I O N - P H A S E 2 42 0 L I N C O L N S T R E E T KA L I S P E L L , M T 5 9 9 0 1 THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF GALLOWAY. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. COPYRIGHT GallowayUS.com 6162 S. Willow Drive, Suite 320 Greenwood Village, CO 80111 303.770.8884 PR E L I M I N A R Y NO T F O R B I D D I N G NO T F O R C O N S T R U C T I O N Date: Drawn By: Project No: Checked By: MPG000001 KDS DJS JANUARY 2025 SITE PLAN C1.0 (5) PP (11) CK (5) PM (20) SW (4) PU (1) PM (1) PM (1) PM (24) HO (5) HO (4) PP(5) HO (19) R4 (9) JM (19) R4 (5) JM (14) R4 (1) JM (6) PP (4) PU (5) SW (6) PP (5) SW (6) PP (5) SW (10) SW (6) PP (1) JM (1) PP (3) SW (10) CK (10) HO(5) JM (4) PP (5) R4(15) BB (15) BB (3) HO (6) PP (9) JM Metal Edger, typical Exist. Landscape Exist. Landscape SYMBOL CODE QTY COMMON NAME BOTANICAL NAME CONT.CAL / SIZE ORNAMENTAL TREES PU 8 MOUNTAIN FROST® USSURIAN PEAR PYRUS USSURIENSIS 'BAILFROST'B&B 2" CAL SYMBOL CODE QTY COMMON NAME BOTANICAL NAME CONT.HT. X SPD. DECIDUOUS SHRUBS PP 44 PAWNEE BUTTES® SAND CHERRY PRUNUS BESSEYI 'P011S'#5 CONT.2`X4` R4 57 CHAMPLAIN SHRUB ROSE ROSA X 'CHAMPLAIN'#5 CONT.3`X3` SW 49 COMMON SNOWBERRY SYMPHORICARPOS ALBUS LAEVIGATUS 'WHITE HEDGE'#5 CONT.6`X4` EVERGREEN SHRUBS JM 30 MOOR-DENSE® JUNIPER JUNIPERUS SABINA 'MONARD'#5 CONT.1`X6` PM 8 MOPS MUGO PINE PINUS MUGO 'MOPS'#5 CONT.5`X5` ORNAMENTAL GRASSES BB 30 BLONDE AMBITION BLUE GRAMA BOUTELOUA GRACILIS 'BLONDE AMBITION'#5 CONT.2`X1.5` CK 22 KARL FOERSTER FEATHER REED GRASS CALAMAGROSTIS X ACUTIFLORA 'KARL FOERSTER'#5 CONT.3`X5` PERENNIALS HO 47 STELLA DE ORO DAYLILY HEMEROCALLIS X 'STELLA DE ORO'#1 CONT.1.5`X1.5` SYMBOL CODE QTY COMMON NAME BOTANICAL NAME TYPE MULCH XS 4,222 SF DARK BROWN SHREDDED MULCH BARK MULCH OTHER SOD TB 3,436 SF KENTUCKY BLUEGRASS SOD TURF OTHER PLANT SCHEDULE - - - - - - - - - - STAMP H:\ F \ F r e d d y s F r o z e n C u s t a r d \ M P G - M o n t a n a P r o p e r t y G r o u p - F r e d d y s \ M T . K a l i s p e l l - M P G - 0 0 0 0 0 1 . 3 0 - F r e d d y s - G r o u n d u p \ 0 P L A \ L 1 . 0 L a n d s c a p e P l a n . d w g - Jo h n S w a i n - 1/5 / 2 0 2 5 Init.#Issue / DescriptionDate PU B L I C I M P R O V E M E N T C O N S T R U C T I O N P L A N S FR E D D Y ' S F R O Z E N C U S T A R D LO T 6 , B L O C K 1 O F T H E K A L I S P E L L N O R T H TO W N S U B D I V I S I O N - P H A S E 2 42 0 L I N C O L N S T R E E T KA L I S P E L L , M T 5 9 9 0 1 THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF GALLOWAY. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. COPYRIGHT GallowayUS.com 6162 S. Willow Drive, Suite 320 Greenwood Village, CO 80111 303.770.8884 PR E L I M I N A R Y NO T F O R B I D D I N G NO T F O R C O N S T R U C T I O N Date: Drawn By: Project No: Checked By: MPG000001 KDS DJS JANUARY 2025 LANDSCAPE PLAN L1.0 SCALE: 1"=20' 0 10 20 Know what's before you dig. 1.THE LANDSCAPE CONTRACTOR IS REQUIRED TO CONTACT THE PUBLIC WORKS DEPARTMENT, AND ANY OTHER PUBLIC OR PRIVATE AGENCY NECESSARY FOR UTILITY LOCATION PRIOR TO ANY CONSTRUCTION. 2.THIS DRAWING IS A PART OF A COMPLETE SET OF BID DOCUMENTS, SPECIFICATIONS, ADDITIONAL DRAWINGS, AND EXHIBITS. UNDER NO CIRCUMSTANCES SHOULD THESE PLANS BE USED FOR CONSTRUCTION PURPOSES WITHOUT EXAMINING ACTUAL LOCATIONS OF UTILITIES ON SITE, AND REVIEWING ALL RELATED DOCUMENTS. 3.THE LOCATION OF THE ALL UNDERGROUND UTILITIES ARE LOCATED ON THE ENGINEERING DRAWINGS FOR THIS PROJECT. THE MOST CURRENT REVISION IS HERE IN MADE PART OF THIS DOCUMENT. UNDERGROUND UTILITIES EXIST THROUGHOUT THIS SITE AND MUST BE LOCATED PRIOR TO ANY CONSTRUCTION ACTIVITY. WHERE UNDERGROUND UTILITIES EXIST, FIELD ADJUSTMENT MAY BE NECESSARY AND MUST BE APPROVED BY A REPRESENTATIVE OF THE OWNER. NEITHER THE OWNER NOR THE LANDSCAPE ARCHITECT ASSUMES ANY RESPONSIBILITY WHATSOEVER, IN RESPECT TO THE CONTRACTORS ACCURACY IN LOCATING THE INDICATED PLANT MATERIAL, AND UNDER NO CIRCUMSTANCES SHOULD THESE PLANS BE USED WITHOUT REFERENCING THE ABOVE MENTIONED DOCUMENTS. UTILITY NOTESIRRIGATION CONCEPT 1.AN AUTOMATIC IRRIGATION SYSTEM SHALL BE INSTALLED AND OPERATIONAL BY THE TIME OF FINAL INSPECTION. THE ENTIRE IRRIGATION SYSTEM SHALL BE INSTALLED BY A QUALIFIED IRRIGATION CONTRACTOR. 2.THE IRRIGATION SYSTEM WILL HAVE APPROPRIATE BACKFLOW PREVENTION DEVICES INSTALLED TO PREVENT CONTAMINATION OF THE WATER SOURCE IF APPLICABLE. 3.ALL NON-TURF/SEED PLANTED AREAS WILL BE DRIP IRRIGATED. TURF SOD/SEED SHALL RECEIVE POP-UP SPRAY IRRIGATION FOR HEAD TO HEAD COVERAGE. 4.ALL PLANTS SHARING SIMILAR HYDROZONE CHARACTERISTICS SHALL BE PLACED ON A VALVE DEDICATED TO PROVIDE THE NECESSARY WATER REQUIREMENTS SPECIFIC TO THAT HYDROZONE. 5.THE IRRIGATION SYSTEM SHALL BE DESIGNED AND INSTALLED, TO THE MAXIMUM EXTENT POSSIBLE, TO CONSERVE WATER BY USING THE FOLLOWING DEVICES AND SYSTEMS: MATCHED PRECIPITATION RATE TECHNOLOGY ON ROTOR AND SPRAY HEADS (WHEREVER POSSIBLE), RAIN SENSORS, AND SMART MULTI-PROGRAM COMPUTERIZED IRRIGATION CONTROLLERS FEATURING SENSORY INPUT CAPABILITIES. 1.THE LANDSCAPE CONTRACTOR SHALL GUARANTEE ALL TREES, SHRUBS, PERENNIALS, SOD, SEEDED AREAS, AND IRRIGATION SYSTEMS FOR A PERIOD OF ONE YEAR FROM THE DATE OF THE OWNER'S ACCEPTANCE. THE CONTRACTOR SHALL REPLACE, AT HIS OWN EXPENSE, ANY PLANTS WHICH DIE IN THAT TIME, OR REPAIR ANY PORTIONS OF THE IRRIGATION SYSTEM WHICH OPERATE IMPROPERLY. 2.THE LANDSCAPE CONTRACTOR SHALL MAINTAIN THE LANDSCAPE IN A NEAT, CLEAN, AND HEALTHY CONDITION FOR A PERIOD OF 90 DAYS. THIS SHALL INCLUDE PROPER PRUNING, MOWING AND AERATION OF LAWNS, WEEDING, REPLACEMENT OF MULCH, REMOVAL OF LITTER, AND THE APPROPRIATE WATERING OF ALL PLANTINGS. IRRIGATION SHALL BE MAINTAINED IN PROPER WORKING ORDER, WITH SCHEDULING ADJUSTMENTS BY SEASON AND TO MAXIMIZE WATER CONSERVATION. IF SITE OPENS DURING WINTER, TO AVOID FREEZE DAMAGE ON PLANTINGS, THE 90 DAYS SHOULD BEGIN AFTER ACCEPTANCE OF THE WORK. 3.DURING THE LANDSCAPE MAINTENANCE PERIOD, THE LANDSCAPE CONTRACTOR SHALL MAINTAIN POSITIVE DRAINAGE AWAY FROM STRUCTURES IN ALL LANDSCAPE AREAS AT THE MINIMUM SLOPE SPECIFIED IN THE GEOTECHNICAL REPORT. LANDSCAPE AREAS WHICH SETTLE AND CREATE THE POTENTIAL FOR PONDING SHALL BE REPAIRED TO ELIMINATE PONDING POTENTIAL AND BLEND IN WITH THE SURROUNDING GRADES. SHOULD ANY CONFLICTS AND/OR DISCREPANCIES ARISE BETWEEN THE GEOTECHNICAL REPORT, THE GRADING PLANS, THESE NOTES, AND ACTUAL CONDITIONS, THE CONTRACTOR SHALL IMMEDIATELY BRING SUCH ITEMS TO THE ATTENTION OF THE LANDSCAPE ARCHITECT AND OWNER. LANDSCAPE GUARANTEE AND MAINTENANCE - - - - - - - - - - STAMP H:\ F \ F r e d d y s F r o z e n C u s t a r d \ M P G - M o n t a n a P r o p e r t y G r o u p - F r e d d y s \ M T . K a l i s p e l l - M P G - 0 0 0 0 0 1 . 3 0 - F r e d d y s - G r o u n d u p \ 0 P L A \ L 2 . 0 L a n d s c a p e P l a n . d w g - Jo h n S w a i n - 1/5 / 2 0 2 5 Init.#Issue / DescriptionDate PU B L I C I M P R O V E M E N T C O N S T R U C T I O N P L A N S FR E D D Y ' S F R O Z E N C U S T A R D LO T 6 , B L O C K 1 O F T H E K A L I S P E L L N O R T H TO W N S U B D I V I S I O N - P H A S E 2 42 0 L I N C O L N S T R E E T KA L I S P E L L , M T 5 9 9 0 1 THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF GALLOWAY. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. COPYRIGHT GallowayUS.com 6162 S. Willow Drive, Suite 320 Greenwood Village, CO 80111 303.770.8884 PR E L I M I N A R Y NO T F O R B I D D I N G NO T F O R C O N S T R U C T I O N Date: Drawn By: Project No: Checked By: MPG000001 KDS DJS JANUARY 2025 LANDSCAPE DETAILS & NOTES L2.0 Know what's before you dig. MIN. 2 X ROOTBALLDIAMETER TH A N R O O T B A L L 4" MIN. TYP. MI N . 6 " D E E P E R 6" MIN. 1 3 4 5 6 FINISH GRADE. SEE PLANTING PLAN FOR GROUND COVER TREATMENT PLANT ROOT BALL. SET TOP ROOTBALL 2" ABOVE ADJACENT GRADE. IN BERMED AREAS SET ROOTBALL 2" ABOVE LOWER ADJACENT GRADE - INSTALL WATER RING (2 - 3" HT.) BACKFILL MIX (PER PLANTING SPECIFICATIONS). AMEND AND FERTILIZE ONLY AS RECOMMENDED IN SOIL FERTILITY ANALYSIS. JET BACKFILL WITH WATER TO ELIMINATE VOIDS. UNDISTURBED NATIVE SOIL. COMPACTED BACKFILL MIX (75%). 1 2 3 4 5 6 SHRUB AND PERENNIAL DETAIL SCALE: NOT TO SCALE1 2 SHREDDED BARK MULCH, 3" MIN. DEPTH, ROUGHLY THE EXTENTS OF ROOTBALL 5 6 7 4 8 9 11 10 12 PREVAILING WINDS NOTES: 1.SCARIFY SIDES OF PLANTING PIT PRIOR TO SETTING TREE. 2.REMOVE EXCESS SOIL APPLIED ON TOP OF THE ROOTBALL THAT COVERS THE ROOT FLARE. THE PLANTING HOLE DEPTH SHALL BE SUCH THAT THE ROOTBALL RESTS ON UNDISTURBED SOIL, AND THE ROOT FLARE IS 3"-5" ABOVE FINISH GRADE. 3.CUT OFF BOTTOM 1/3 OF WIRE BASKET BEFORE PLACING TREE IN HOLE, CUT OFF AND REMOVE REMAINDER OF BASKET AFTER TREE IS SET IN HOLE, REMOVE ALL NYLON TIES, TWINE, ROPE, AND OTHER PACKING MATERIAL. REMOVE ALL BURLAP FROM AROUND ROOTBALL. 4.TREE WRAP IS NOT TO BE USED ON ANY NEW PLANTINGS, EXCEPT IN LATE FALL PLANTING SITUATIONS, AND ONLY THEN AFTER CONSULTATION WITH THE LANDSCAPE ARCHITECT. WHEN WRAPPING TREE, WRAP FROM TRUNK FLARE TO LOWEST MAJOR BRANCH. 5.REMOVE ALL NURSERY STAKES AFTER PLANTING. 6.FOR TREES OVER 3" CALIPER, USE THREE STAKES OR DEADMEN (AS APPROPRIATE), SPACED EVENLY AROUND TREE. 7.DO NOT ALLOW AIR POCKETS TO FORM WHEN BACKFILLING. 1 2 3 TREE CANOPY. NYLON TREE STRAPS AT ENDS OF WIRES - SECURE TO STAKE OR DEADMEN WITH NAILS. 12 GAUGE GALVANIZED WIRE. SECURE TO TRUNK JUST ABOVE LOWEST MAJOR BRANCHES. PRESSURE-TREATED WOOD STAKE, 2" DIA. EXTEND STAKES 12" MIN. INTO UNDISTURBED SOIL. 24" X 3/4" P.V.C. MARKERS OVER WIRES. PRESSURE-TREATED WOOD DEADMEN, TWO PER TREE (MIN.). BURY OUTSIDE OF PLANTING PIT AND 18" MIN. INTO UNDISTURBED SOIL. WOOD MULCH TREE RING 3' DIA MIN. TYPE AND DEPTH PER PLANS. DO NOT PLACE MULCH WITHIN 3" OF TRUNK. FINISH GRADE. SEE PLANTING PLAN FOR GROUND COVER TREATMENT BACKFILL. AMEND AND FERTILIZE ONLY AS RECOMMENDED IN SOIL FERTILITY ANALYSIS. ROOT BALL-SEE NOTE 3, THIS DETAIL UNDISTURBED NATIVE SOIL TRUNK FLARE. PREVAILING WINDS STAKING EXAMPLES (PLAN VIEW) 1 5 6 TREE PLANTING DETAIL SCALE: NOT TO SCALE2 EVERGREEN TREE DECIDUOUS TREE 1 2 5 7 8 9 10 11 12 3 4 6 3X ROOTBALL DIA. 13 13 SOFT VELCRO, OR OTHER FABRIC WRAP 14 14 CENTRAL LEADER, SEE PLANTING NOTES LANDSCAPE BOULDER DETAIL SCALE: NOT TO SCALE3 FINISH GRADE1 1/3 TO 1/2 OF BOULDER SHALL BE BURIED 2 COMPACTED SUBGRADE3 HARVEST BOULDERS OF VARYING SIZES FROM A LOCAL SOURCE, PROVIDE SOURCE AND PICTURES OF NON-FRACTURED DECORATIVE BOULDERS.4 4 2 3 1 PLANTING NOTES GENERAL 1.ALL WORK SHALL CONFORM TO ALL APPLICABLE STATE AND LOCAL CODES, STANDARDS, AND SPECIFICATIONS. 2.LANDSCAPE DESIGN IS DIAGRAMMATIC IN NATURE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR HIS OWN TAKEOFFS AND QUANTITY CALCULATIONS. IN THE EVENT OF A DISCREPANCY BETWEEN THE PLAN AND THE LANDSCAPE LEGEND, THE PLANT QUANTITY AS SHOWN ON THE PLAN SHALL TAKE PRECEDENCE AND NOTIFY THE LANDSCAPE ARCHITECT OF THESE DISCREPANCIES. MINOR ADJUSTMENTS TO THE LANDSCAPE MATERIAL AND LOCATIONS MAY BE PROPOSED FOR CITY CONSIDERATION AT THE CONSTRUCTION DOCUMENT STAGE TO RESPOND TO MARKET AND FIELD CONDITIONS. HOWEVER, THERE SHALL BE NO REDUCTION IN THE NUMBER AND SIZE OF MATERIALS. 3.CONTRACTOR SHALL MAKE HIMSELF AWARE OF THE LOCATIONS OF EXISTING AND PROPOSED UTILITIES, AND SHALL BE RESPONSIBLE FOR ANY DAMAGE TO THE UTILITIES AND/OR ANY INJURY TO ANY PERSON. THIS DRAWING IS PART OF A COMPLETE SET OF CONTRACT DOCUMENTS. UNDER NO CIRCUMSTANCES SHOULD THIS PLAN BE USED FOR CONSTRUCTION PURPOSES WITHOUT EXAMINING ACTUAL LOCATIONS OF UTILITIES ON SITE AND REVIEW ALL RELATED PLANS AND DOCUMENTS. 4.ALL UTILITY EASEMENTS SHALL REMAIN UNOBSTRUCTED AND FULLY ACCESSIBLE ALONG THEIR ENTIRE LENGTH FOR MAINTENANCE EQUIPMENT. 5.THE CONTRACTOR SHALL TAKE EXTREME CARE NOT TO DAMAGE ANY EXISTING PLANTS INDICATED AS "TO REMAIN". ANY SUCH PLANTS DAMAGED BY THE CONTRACTOR SHALL BE REPLACED WITH THE SAME SPECIES, SIZE, AND QUANTITY AT THE CONTRACTOR'S OWN EXPENSE, AND AS ACCEPTABLE TO THE OWNER. REFER TO THE TREE PROTECTION NOTES ON THE PLANS (AS APPLICABLE). 6.LANDSCAPE CONTRACTOR SHALL EXAMINE THE SITE CONDITIONS UNDER WHICH THE WORK IS TO BE PERFORMED AND NOTIFY THE GENERAL CONTRACTOR IN WRITING OF UNSATISFACTORY CONDITIONS. IF SITE CONDITIONS OR PLANT AVAILABILITY REQUIRE CHANGES TO THE PLAN, THEN AN APPROVAL WILL BE OBTAINED FROM THE CITY. DO NOT PROCEED UNTIL CONDITIONS HAVE BEEN CORRECTED. 7.ALL CONSTRUCTION DEBRIS AND MATERIAL SHALL BE REMOVED AND CLEANED OUT PRIOR TO INSTALLATION OF TOPSOIL, TREES, SHRUBS, AND TURF. 8.FOR ALL INFORMATION ON SURFACE MATERIAL OF WALKS, DRIVES, AND PARKING LOTS, SEE THE SITE PLAN. SEE PHOTOMETRIC PLAN FOR FREE STANDING LIGHTING INFORMATION. 9.THE LANDSCAPE CONTRACTOR SHALL NOTIFY THE LANDSCAPE ARCHITECT ONE WEEK PRIOR TO BEGINNING CONSTRUCTION. 10.WINTER WATERING SHALL BE AT THE EXPENSE OF THE CONTRACTOR UNTIL SUCH TIME AS FINAL ACCEPTANCE IS RECEIVED. 11.ALL LANDSCAPE CONSTRUCTION PRACTICES, WORKMANSHIP, AND ETHICS SHALL, BE IN ACCORDANCE WITH INDUSTRY STANDARDS SET FORTH IN THE CONTRACTORS HANDBOOK AND/OR STANDARDS PUBLISHED BY THE MONTANA LANDSCAPE CONTRACTORS ASSOCIATION. 12.LANDSCAPE AND IRRIGATION WORK SHALL BE COMPLETED PRIOR TO THE ISSUANCE OF THE FINAL CERTIFICATE OF OCCUPANCY. FINISH GRADING AND SOIL PREPARATION 13.CONTRACTOR SHALL CONSTRUCT AND MAINTAIN FINISH GRADES AS RECOMMENDED BY THE GEOTECHNICAL REPORT. ALL LANDSCAPE AREAS SHALL HAVE POSITIVE DRAINAGE AWAY FROM STRUCTURES AT THE MINIMUM SLOPE SPECIFIED IN THE REPORT, AND AREAS OF POTENTIAL PONDING SHALL BE REGRADED TO BLEND IN WITH THE SURROUNDING GRADES AND ELIMINATE PONDING POTENTIAL. SHOULD ANY CONFLICTS AND/OR DISCREPANCIES ARISE BETWEEN THE GEOTECHNICAL REPORT, THE GRADING PLANS, THESE NOTES, AND ACTUAL CONDITIONS, THE CONTRACTOR SHALL IMMEDIATELY BRING SUCH ITEMS TO THE ATTENTION OF THE LANDSCAPE ARCHITECT AND OWNER. 14.AFTER FINISH GRADES HAVE BEEN ESTABLISHED, IT IS RECOMMENDED THAT THE CONTRACTOR SHALL HAVE SOIL SAMPLES TESTED BY AN ESTABLISHED SOIL TESTING LABORATORY FOR THE FOLLOWING: GENERAL SOIL FERTILITY, PH, ORGANIC MATTER CONTENT, SALT (CEC), LIME, SODIUM ABSORPTION RATIO (SAR) AND BORON CONTENT. EACH SAMPLE SUBMITTED SHALL CONTAIN NO LESS THAN ONE QUART OF SOIL. CONTRACTOR SHALL ALSO SUBMIT THE PROJECT'S PLANT LIST TO THE LABORATORY ALONG WITH THE SOIL SAMPLES. THE SOIL REPORT PRODUCED BY THE LABORATORY SHALL CONTAIN RECOMMENDATIONS FOR THE FOLLOWING (AS APPROPRIATE): GENERAL SOIL PREPARATION AND BACKFILL MIXES, PRE-PLANT FERTILIZER APPLICATIONS, AND ANY OTHER SOIL RELATED ISSUES. THE REPORT SHALL ALSO PROVIDE A FERTILIZER PROGRAM FOR THE ESTABLISHMENT PERIOD AND FOR LONG-TERM MAINTENANCE. 15.THE CONTRACTOR SHALL RECOMMEND INSTALLATION OF SOIL AMENDMENTS AND FERTILIZERS PER THE SOILS REPORT FOR THE THE OWNER/OWNER'S REPRESENTATIVE CONSIDERATION. 16.AT A MINIMUM, ALL TOPSOIL SHALL BE AMENDED WITH NITROGEN STABILIZED ORGANIC AMENDMENT COMPOST AT A RATE OF 5.0 CUBIC YARDS AND AMMONIUM PHOSPHATE 16-20-0 AT A RATE OF 15 POUNDS PER THOUSAND SQUARE FEET OF LANDSCAPE AREA. COMPOST SHALL BE MECHANICALLY INTEGRATED INTO THE TOP 6" OF SOIL BY MEANS OF ROTOTILLING AFTER CROSS-RIPPING. GROUND COVER & PERENNIAL BED AREAS SHALL BE AMENDED AT A RATE OF 8 CUBIC FEET PER THOUSAND SQUARE FEET OF NITROGEN STABILIZED ORGANIC AMENDMENT AND 10 LBS. OF 12-12-12 FERTILIZER PER CU. YD., ROTOTILLED TO A DEPTH OF 8". NO MANURE OR ANIMAL-BASED PRODUCTS SHALL BE USED FOR ORGANIC AMENDMENTS. 17.ALL PARKING ISLAND SOIL TO BE TILLED OR AMENDED TO A MINIMUM DEPTH OF 30". PLANTING 18.ALL DECIDUOUS TREES SHALL HAVE FULL, WELL-SHAPED HEADS/ALL EVERGREENS SHALL BE UNSHEARED AND FULL TO THE GROUND; UNLESS OTHERWISE SPECIFIED. TREES WITH CENTRAL LEADERS WILL NOT BE ACCEPTED IF LEADER IS DAMAGED OR REMOVED. PRUNE ALL DAMAGED TWIGS AFTER PLANTING. 19.ALL PLANTS WITHIN A SPECIES SHALL HAVE SIMILAR SIZE, AND SHALL BE OF A FORM TYPICAL FOR THE SPECIES. ANY PLANT DEEMED UNACCEPTABLE BY THE LANDSCAPE ARCHITECT SHALL BE IMMEDIATELY REMOVED FROM THE SITE AND SHALL BE REPLACED WITH AN ACCEPTABLE PLANT OF LIKE TYPE AND SIZE AT THE CONTRACTOR'S OWN EXPENSE. ANY PLANTS APPEARING TO BE UNHEALTHY, EVEN IF DETERMINED TO STILL BE ALIVE, SHALL NOT BE ACCEPTED. THE LANDSCAPE ARCHITECT SHALL BE THE SOLE JUDGE AS TO THE ACCEPTABILITY OF PLANT MATERIAL. 20.ALL TREES SHALL BE GUYED AND WOOD STAKED AS PER DETAILS. NO 'T-STAKES' SHALL BE USED FOR TREES. 21.ALL PLANT MATERIALS SHALL BE TRUE TO TYPE, SIZE, SPECIES, QUALITY, AND FREE OF INJURY, BROKEN ROOT BALLS, PESTS, AND DISEASES, AS WELL AS CONFORM TO THE MINIMUM REQUIREMENTS DESCRIBED IN THE "AMERICAN STANDARD FOR NURSERY STOCK". FOLLOW GREENCO TREE PLANTING RECOMMENDATIONS FOR MINIMUM QUALITY REQUIREMENTS FOR TREES. 22.ALL TREE AND SHRUB BED LOCATIONS ARE TO BE STAKED OUT ON SITE FOR APPROVAL BY THE LANDSCAPE ARCHITECT PRIOR TO INSTALLATION. 23.ALL TREES PLANTED ADJACENT TO PUBLIC AND/OR PEDESTRIAN WALKWAYS SHALL BE PRUNED CLEAR OF ALL BRANCHES BETWEEN GROUND AND A HEIGHT OF EIGHT (8) FEET FOR THAT PORTION OF THE PLAN LOCATED OVER THE SIDEWALK AND/OR ROAD. 24.ALL PLANT MATERIAL SHALL NOT BE PLANTED PRIOR TO INSTALLATION OF TOPSOIL. 25.ALL PLANT BEDS SHALL BE CONTAINED WITH STEEL EDGER. STEEL EDGER IS NOT REQUIRED ALONG CURBS, WALKS OR BUILDING FOUNDATIONS. ALL EDGING SHALL OVERLAP AT JOINTS A MINIMUM OF 6-INCHES, AND SHALL BE FASTENED WITH A MINIMUM OF 4 PINS PER EACH 10 FOOT SECTION. THE TOP OF ALL EDGING MATERIAL SHALL BE A ROLLED TOP AND 1/2 INCH ABOVE THE FINISHED GRADE OF ADJACENT LAWN OR MULCH AREAS. COLOR: GREEN. 26.THE DEVELOPER, HIS SUCCESSOR, OR ASSIGNEE SHALL BE RESPONSIBLE FOR ESTABLISHING AND CONTINUING A REGULAR PROGRAM OF MAINTENANCE FOR ALL LANDSCAPED AREAS. SEE LANDSCAPE GUARANTEE AND MAINTENANCE NOTE. 27.A 3-FOOT CLEAR SPACE SHALL BE MAINTAINED AROUND THE CIRCUMFERENCE OF ALL FIRE HYDRANTS. 28.LANDSCAPE CONTRACTOR TO SUBMIT SAMPLES OF MISCELLANEOUS LANDSCAPING MATERIALS TO THE LANDSCAPE ARCHITECTS AND OWNER'S REPRESENTATIVE FOR APPROVAL PRIOR TO INSTALLATION, IE.; MULCH, EDGER, LANDSCAPE FABRIC, ETC. MULCHING 29.AFTER ALL PLANTING IS COMPLETE, THE CONTRACTOR SHALL INSTALL A MINIMUM 4" THICK LAYER OF MULCH AS SPECIFIED IN THE PLANTING LEGEND. INSTALL A 4" THICK RING OF DOUBLE SHREDDED CEDAR BARK MULCH AROUND ALL PLANT MATERIAL IN ROCK MULCH BEDS WHERE LANDSCAPING IS SHOWN ON THE PLANS. WOOD MULCH RING SIZE SHALL BE THE CONTAINER SIZE OF THE SHRUBS, PERENNIALS, AND ORNAMENTAL GRASSES. TREE RING SIZE SHALL A MIN OF 3' DIA. 30.ALL MULCH SHALL BE HARVESTED IN A SUSTAINABLE MANNER FROM A LOCAL SOURCE. 31.INSTALL DEWITT PRO-5 WEED BARRIER FABRIC UNDER ALL ROCK MULCH SHRUB BEDS SPECIFIED ON THE PLANS ONLY. NO LANDSCAPE FABRIC SHALL BE USED IN WOOD MULCH AREAS. NO PLASTIC WEED BARRIERS SHALL BE SPECIFIED. 32.ABSOLUTELY NO EXPOSED GROUND SHALL BE LEFT SHOWING ANYWHERE ON THE PROJECT AFTER MULCH HAS BEEN INSTALLED. 33.ALL PLANTING AREAS WITH LESS THAN A 4:1 GRADIENT SHALL RECEIVE A LAYER OF MULCH, TYPE AND DEPTH PER PLANS. SUBMIT 1 CUBIC FOOT SAMPLE OF MULCH (ONE SAMPLE PER TYPE) TO LANDSCAPE ARCHITECT FOR APPROVAL PRIOR TO INSTALLATION. THE MULCH SHALL BE SPREAD EVENLY THROUGHOUT ALL PLANTING AREAS EXCEPT SLOPES 4:1 OR STEEPER, OR AS OTHERWISE DENOTED ON THE PLAN. ABSOLUTELY NO EXPOSED GROUND SHALL REMAIN IN AREAS TO RECEIVE MULCH AFTER MULCH HAS BEEN INSTALLED. 34.ALL PLANTING AREAS ON SLOPES OVER 4:1 SHALL RECEIVE COCONUT FIBER EROSION CONTROL NETTING FROM ROLLS. NETTING SHALL BE #CT-125, AS MANUFACTURED BY NORTH AMERICAN GREEN (OR EQUAL). INSTALL AND STAKE PER MANUFACTURER'S SPECIFICATIONS. SEE ALSO THE CIVIL ENGINEER'S EROSION CONTROL PLAN. 4 1 2 3 3/4" X 4" RYERSON STEEL EDGER OR APPROVED EQUAL FINISH GRADE 16" STAKES AT 30" O.C. 4" DEPTH MULCH OVER WEED BARRIER. LANDSCAPE EDGER DETAIL SCALE: NOT TO SCALE4 3 2 5 LAWN / SOD 5 4 1 CO CO CO CO CO CO CO CO CO THRU DRIVE 400 S Emporia, Suite 300 Wichita, KS 67202 316.368.5444 DATE: PROGRESS PRINTNOT FOR CONSTRUCTIONFIL E P A T H : DATE: PROJECT NO: CHECKED BY: DRAWN BY: STORE NO:7222 1/6/2025 10:47:36 AM Au t o d e s k D o c s : / / M P G 0 0 0 0 0 1 - M P G - - M T K a l i s p e l l - - F r e d d y s -G r o u n d - U p - ( B / M P G 0 0 0 0 0 1 . 3 0 - F r e d d y s - M T - K a l l i s p e l l - 0 8 -0 3 - A E - R 2 4 . r v t SITE PLAN CP-100 MPG000001.30 01.06.2025 Checker Fr e d d y ' s F r o z e n C u s t a r d KA L I S P E L L , M T 5 9 9 0 1 42 0 C A S S C A D E L O O P Author 0 10' 20'1" = 10'-0"1 SITE PLAN DESCRIPTION DATE NORTH EP-1 EP-1 EP-3 EP-3 T4 T4T1 T2T2 T2 T2 B1A B1B B1B B1B B1A KITCHEN DINING T1T1 T1T1T1 T1T1 400 S Emporia, Suite 300 Wichita, KS 67202 316.368.5444 DATE: PROGRESS PRINTNOT FOR CONSTRUCTIONFIL E P A T H : DATE: PROJECT NO: CHECKED BY: DRAWN BY: STORE NO: 7222 1/6/2025 10:47:37 AM Au t o d e s k D o c s : / / M P G 0 0 0 0 0 1 - M P G - - M T K a l i s p e l l - - F r e d d y s -G r o u n d - U p - ( B / M P G 0 0 0 0 0 1 . 3 0 - F r e d d y s - M T - K a l l i s p e l l - 0 8 -0 3 - A E - R 2 4 . r v t FLOOR PLAN CP-200 MPG000001.30 01.06.2025 KM Fr e d d y ' s F r o z e n C u s t a r d KA L I S P E L L , M T 5 9 9 0 1 42 0 C A S S C A D E L O O P IDP 0 4' 8'2'1/4" = 1'-0"1 FLOOR PLAN NEW CONSTRUCTION NORTH SMALL PROTO-TYPE WITH VESTIBULE BUILDING AREA (N.I.C. WALK0IN) = 2,508 SQ FT BUILDING AREA (TOTAL)=2,731 SQ FT SEAT COUNT -INTERIOR SEAT COUNT = 52 -PATIO SEAT COUNT = 12 OCCUPANT LOAD (BASED OF AREA) -INTERIOR OCCUPANCY COUNT = 79 OCCUPANTS -EXTERIOR PATIO = 12 OCCUPANTS DESCRIPTION DATE FIRST FLOOR 100' - 0" T.O. HIGH PARAPET 123' - 7" T.O. LOW PARAPET 120' - 7" 11'-4 3/4"59'-9 1/2"3'-10 3/4"4'-4 1/2" 79'-5 1/2" DASHED LINE IS AN LED STRIP LIGHT SHIELDED BY COMPRESSION CAP DASHED LINE IS AN LED STRIP LIGHT SHIELDED BY COMPRESSION CAP 62.25 SF COPY AREA 19.6 SF COPY AREA FIRST FLOOR 100' - 0" 6.T.O. INT. PARAPET 122' - 1" T.O. HIGH PARAPET 123' - 7" T.O. LOW PARAPET 120' - 7" 3'-10 1/4"70'-1 1/2"4'-0 1/2" 78'-0 1/4" DASHED LINE IS AN LED STRIP LIGHT SHIELDED BY COMPRESSION CAP 18 SF COPY AREA 6.6 SF COPY AREA 19.6 SF COPY AREA FIRST FLOOR 100' - 0" 6.T.O. INT. PARAPET 122' - 1" T.O. HIGH PARAPET 123' - 7" 4'-3 3/4"20'-4 1/2"11'-3" 35'-11 1/4" DASHED LINE IS AN LED STRIP LIGHT SHIELDED BY COMPRESSION CAP 62.25 SF COPY AREA FIRST FLOOR 100' - 0" 6.T.O. INT. PARAPET 122' - 1" T.O. LOW PARAPET 120' - 7" 4'-7 1/4"17'-4 3/4"8'-7"3'-8 1/4" 34'-3 1/4" DASHED LINE IS AN LED STRIP LIGHT SHIELDED BY COMPRESSION CAP MATERIAL LEGEND DRYVIT 386 A Pure Cream DRYVIT 614 Smoke Signal MARION CERAMICS 410 Gunstock Brown NICHIHA VINTAGE WOOD Cedar 400 S Emporia, Suite 300 Wichita, KS 67202 316.368.5444 DATE: PROGRESS PRINTNOT FOR CONSTRUCTIONFIL E P A T H : DATE: PROJECT NO: CHECKED BY: DRAWN BY: STORE NO: 7222 1/6/2025 10:47:42 AM Au t o d e s k D o c s : / / M P G 0 0 0 0 0 1 - M P G - - M T K a l i s p e l l - - F r e d d y s -G r o u n d - U p - ( B / M P G 0 0 0 0 0 1 . 3 0 - F r e d d y s - M T - K a l l i s p e l l - 0 8 -0 3 - A E - R 2 4 . r v t ELEVATIONS CP-300 MPG000001.30 01.06.2025 KM Fr e d d y ' s F r o z e n C u s t a r d KA L I S P E L L , M T 5 9 9 0 1 42 0 C A S S C A D E L O O P IDP 0 4' 8'2'1/4" = 1'-0"D EAST ELEVATION 0 4' 8'2'1/4" = 1'-0"C WEST ELEVATION 0 4' 8'2'1/4" = 1'-0"B SOUTH ELEVATION 0 4' 8'2'1/4" = 1'-0"A NORTH ELEVATION EXTERIOR MATERIALS SOUTH 04 - Masonry - Brick, Running Bond-GUNSTOCK 610 159 SF 10% 08 - Openings - Glass, Clear 81 SF 5% Paint-Dryvit #386a Pure Cream 1345 SF 85% 1585 SF EXTERIOR MATERIALS WEST 04 - Masonry - Brick, Running Bond-GUNSTOCK 610 118 SF 17% Cladding - Fiber Cement - Nichiha - Woodgrain - VintageWood 1818 - Horizontal - Matte - Cedar with 5/8" Clip (JE778)-GUNSTOCK 177 SF 26% Paint-Dryvit #386a Pure Cream 388 SF 57% 682 SF EXTERIOR MATERIALS EAST 04 - Masonry - Brick, Running Bond-GUNSTOCK 610 282 SF 37% 08 - Openings - Glass, Clear 177 SF 23% Paint-Dryvit #386a Pure Cream 312 SF 40% 771 SF EXTERIOR MATERIALS NORTH 04 - Masonry - Brick, Running Bond-GUNSTOCK 610 336 SF 18% 08 - Openings - Glass, Clear 121 SF 7% Cladding - Fiber Cement - Nichiha - Woodgrain - VintageWood 1818 - Horizontal - Matte - Cedar with 5/8" Clip (JE778)-GUNSTOCK 172 SF 9% Paint-Dryvit #386a Pure Cream 1218 SF 66% 1847 SF EXTERIOR MATERIALS 04 - Masonry - Brick, Running Bond-GUNSTOCK 610 1085 SF 19% 08 - Openings - Glass, Clear 578 SF 10% Cladding - Fiber Cement - Nichiha - Woodgrain - VintageWood 1818 - Horizontal - Matte - Cedar with 5/8" Clip (JE778)-GUNSTOCK 488 SF 8% Paint-Dryvit #386a Pure Cream 3640 SF 63% 5792 SF DESCRIPTION DATE MATERIAL LEGEND DRYVIT 386 A Pure Cream DRYVIT 614 Smoke Signal MARION CERAMICS 410 Gunstock Brown NICHIHA VINTAGE WOOD Cedar 109' - 1" 106' - 9" T.O. ROOF T.O. WALL 109' - 1" T.O. ROOF 109' - 1" 106' - 9" T.O. ROOF T.O. WALL 109' - 1" 106' - 9" T.O. ROOF T.O. WALL 400 S Emporia, Suite 300 Wichita, KS 67202 316.368.5444 DATE: PROGRESS PRINTNOT FOR CONSTRUCTIONFIL E P A T H : DATE: PROJECT NO: CHECKED BY: DRAWN BY: STORE NO: 7222 1/6/2025 10:47:42 AM Au t o d e s k D o c s : / / M P G 0 0 0 0 0 1 - M P G - - M T K a l i s p e l l - - F r e d d y s -G r o u n d - U p - ( B / M P G 0 0 0 0 0 1 . 3 0 - F r e d d y s - M T - K a l l i s p e l l - 0 8 -0 3 - A E - R 2 4 . r v t TRASH ENCLOSURE ELEVATIONS CP-301 MPG000001.30 01.06.2025 KM Fr e d d y ' s F r o z e n C u s t a r d KA L I S P E L L , M T 5 9 9 0 1 42 0 C A S S C A D E L O O P IDP H WEST ELEVATION F SOUTH ELEVATION E NORTH ELEVATION G EAST ELEVATION DESCRIPTION DATE EXTERIOR SIGNAGE BUILDING AND SITE GUIDELINES SIGNAGE – BUILDING AND SITE GUIDELINES These guidelines set fourth Freddy’s general requirements for signage at your site. These guidelines may need to be revised by your signage vendor to comply with various factors at your specific site which may include, but are not limited to, governmental requirements, construction requirements and engineering requirements. You should work closely with your signage vendor to design and construct signage which complies with the guidelines set forth herein and specific requirements of your site. Freddy’s requires that any approved Sign Vendor meets or exceeds the specifications set forth in these guidelines. Franchisees requesting a sign vendor be considered that is not approved, much submit for consideration. Submittal for considerations is reviewed by the Construction Department at the time of submittal. Prior or one-time usage of a sign vendor does not guarantee future approval. SIGN DETAILS, PLANS, DRAWINGS AND COMPLETE SHOP DRAWINGS AS OUTLINED IN THIS SECTIONS SHOULD BE SUBMITTED TO THE CONSTRUCTION DEPARTMENT, DURING THE PLANNING STAGES OF THE STORE PROJECT, FOR REVIEW AND APPROVAL AS PART OF THE BRAND STANDARD APPROVAL PROCESS. These guidelines cover the following: Channel Letter and Food Words Monument and Pole Signage Multi-Tenant Signage Directional Signage Freddy’s Interior Signage Reader Boards SIGNAGE – BUILDING AND SITE GUIDELINES A. SUBMITTALS 1. THE ARCHITECT AND SIGNAGE VENDOR SHOULD BOTH RESEARCH ALL SIGNAGE CODES 2. THE FOLLOWING DRAWINGS CAN BE SUBMITTED BY THE SIGNAGE MANUFACTUREER ON BEHALF OF THE FRANCHISEE OR THE FRANCHSIEE CAN SUBMIT THEM DIRECTLY TO FREDDY’S CONSTRUCTION DEPARTMENT FOR REVIEW AND APPROVAL 3. Shop drawings showing signage should include the following details. a. All signage can materials and all sizes including overall dimensions. b. Relationship of sign placement to lighting on building. c. UL labels required. d. LED module connection details and specifications. e. Connection details. f. Material Information. g. LED connection details, power supply and specifications. h. All other applicable information. 4. Samples shall be made available on request to Freddy’s Corporate for any new sign product or component for review, testing or compliance. 5. All work and materials must conform to applicable performance standards and specifications. B. WARRANTY 1. All signage claim issues shall be handled by the sign vendor. 2. Signage installation shall be warranted for 5 years by signage installer. 3. Sign cans including framework, shall be warranted against defective material and workmanship for a period of 10 years by the signage manufacturer. 4. LEDs shall be warranted for 3 years by the LED manufacturer. 5. LED power supplies shall be warranted for 3 years by the LED manufacturer. 6. It is unlikely that the bulbs or ballast will fail in the first year. If they do, the bulbs, ballasts and labor for replacement will be replaced at no charge by the sign vendor. 7. Labor on electrical shall be warranted for 1 year by electrical installer. C. FABRICATION GUILDINES 1. To the greatest extent possible, signage should be pre-assembled by the manufacturer to minimize onsite assembly. 2. Ensure welds are provided behind finished surfaces and transmit no distortion or discoloration to the finished side. 3. Joints, miters and connections should be tight and free of noticeable fractures. 4. Acrylic faces are to be continuous, without splices or seamed inside the housings. 5. Fasteners shall be fully concealed wherever possible. SIGNAGE – BUILDING AND SITE GUIDELINES 6. Sign posts should be fabricated to lengths required for the mounting method indicated. Options for mounting posts are as follows: a. Direct Ground Burial i. Fabricate sign posts a minimum of 36 inches longer than the height indicated for the sign to allow for embedding into concrete foundation. ii. This method allows for permanent installation of the sign or as code dictates. iii. If not permanently installing, use a spread footing or base plate method. b. Base Plate Method i. For removable installations, posts shall be fitted with welded face plates. ii. Holes shall be predrilled by the manufacturer to accommodate anchor bolt connections to a concrete foundation. iii. Furnish templates as required for accurate setting of anchor bolt locations. iv. All post heights over 72 inches shall be gusseted of otherwise reinforced. D. INSTALLATION GUIDELINES – Channel Letters, Food Words, Monument and Pole Signs 1. Materials shall be wrapped for shipment and storage and delivered to the job site in manufacture’s original packaging. Freight to be arranged by sign manufacturer, unloaded, and installed by a licensed sign installed specialized in performing sign installations. 2. Installation shall be structurally sound to avoid warps, buckles, distortions, opening up of joints or overstressing of welds and fasteners. 3. Coordinate installation with adjacent finish materials in a manner not to destroy adjacent surfaces. 4. Building penetrations shall be appropriately sealed and water tight. 5. Locate and install signs in locations indicated on drawings in accordance with approved shop drawings. 6. For direct burial installations, bore required holes to a diameter at least 4 times as large as the largest post cross-section and to a minimum depth of a least 36 inches (914 mm) below grade. The post section that will be below-grade shall be covered with a bituminous coating to prevent oxidation. Place gravel, sand, or crushed stone in the bored hole to allow for proper drainage. Place concrete around the post and ensure the unit is square, level, and plumb. 7. For base mounted installations, set unit on prepared base and secure with anchor bolts. Secure joint between module and base. Confirm that the unit is square, level, and plumb. 8. Signage permits will be secured by signage vendor in agreement with the owner. 9. Fasteners shall be appropriate for the mounting substrate. Furnish templates as required for accurate setting of anchor bolt locations. 10. All signage free of blemishes and clean of any substance that might discolor or damage surfaces. SIGNAGE – ILLUMINATED CHANNEL LETTERS E. CHANNEL LETTERS – ILLUMUNATED – FREDDY’S FRONT, SIDES AND BACK OF BUILDING – PRIMARY ELEVATION MAXIMIZE SIZE OF SIGN ON EACH ELEVATION AS CODE ALLOWS *Not the same construction as illuminated food words 1. 3” pre-painted semi-gloss aluminum returns (Black). 2. .177 #7328 white modified acrylic faces with 1st surface 3M High Performance 3630-33 red vinyl overlays. Acrylic faces are to be continuous, without splices or seamed inside the housings. 3. 1” Jewelite trim cap (Black). 4. Internal LED Illumination is Principal Sloan Quikmod 2 (White). 5. Pre-Painted WHITE Aluminum or ACM backs. 6. Letter attachment with non-corrosive securement as required per location (typical anchor screwed into plywood behind EIFS). 7. Principal Sloan remote power supply in aluminum box as required. 8. 20Amp (120 Volt) disconnect switch. 9. Double wire thru Sealtite conduit (6” from bottom of letters) to power supply in galvanized box behind wall (primary connection by licensed electrical contractor). 10. 120 volt G.C. or Landlord supplied power supply, 2 -8 amps per sign, depending on the size. 11. ¼” diameter weep holes in low points of letters/elements. Each letter to be UL approved and individually marked by a UL label. The Registered Trademark symbol ® is NOT part of the Illuminated Channel Letters when they are on the building. SIGNAGE – ILLUMINATED CHANNEL LETTERS *Acrylic faces are to be continuous, without splices or seamed inside the housings. SIGNAGE – NON-ILLUMINATED FOOD WORDS F. GEMINI LETTERS – NON-ILLUMINATED FOOD WORDS – STEAKBURGERS, FROZEN CUSTARD, FRIES (or SHAKES) GOOSENECK LIGHTS REQUIRED ABOVE SIGNAGE WHEN CODE DOES NOT ALLOW FOOD WORDS, 6 GOOSENECKS NEED TO BE PLACED ON THE RIGHT AND LEFT SIDES OF THE BUILDING 1. Stud mounted 15” Gemini letters. 2. Formed plastic letters, made from earth friendly CAB plastic that is durable, weather resistant and dimensional. 3. Font – Century Schoolbook Bold round face. 4. Finish – 2793 red pigmented material, unpainted 5. Letter attachment with non-corrosive securement as required per location. 6. Food Word Letters never in white. SIGNAGE – ILLUMINATED FOOD WORDS G. CHANNEL LETTERS – ILLUMIANTED FOOD WORDS – STEAKBURGERS, FROZEN CUSTARD, FRIES (or SHAKES) 2 GOOSENECK LIGHTS ON EITHER SIDE OF FOOD WORD. TOTAL OF 6 GOOSENECKS PER SIDE OF BUILDING 1. 3” pre-painted semi-gloss aluminum returns (Black). 2. .177 #7328 white modified acrylic faces with 1st surface 3M High Performance 3630-33 red vinyl overlays. 3. 1” Jewelite trim cap (Black). 4. Internal LED Illumination is Principal Sloan Quikmod 2 (White). 5. Pre-Painted WHITE Aluminum or ACM backs. 6. Letter attachment with non-corrosive securement as required per location (typical anchor screwed into plywood behind EIFS). 7. Principal Sloan remote power supply in aluminum box as required. 8. 20Amp (120 Volt) disconnect switch. 9. Double wire thru Sealtite conduit (6” from bottom of letters) to power supply in galvanized box behind wall (primary connection by licensed electrical contractor). 10. 120 volt G.C. or Landlord supplied power supply, 2 -8 amps per sign, depending on the size. 11. ¼” diameter weep holes in low points of letters/elements. Each letter to be UL approved and individually marked by a UL label. SIGNAGE – POLE SIGN H. POLE SIGN 1. Double face internally illuminated pole sign, fewer than 100 sq. ft. fabricated of 1-1/2” angle iron frame or over 100 sq. ft. 2-1/2” angle iron 2. Skinned with .050 aluminum at minimum, sign company to ensure proper material thickness to prevent oil- canning. Painted to match PMS 186C with 4” aluminum retainer. 3. Face is WHITE Panaflex with vinyl graphics applied to the first surface. 4. Both cabinet faces have 3M High Performance 3630-033 RED translucent vinyl graphics applied to the first surface and are both illuminated by LED lamps powered by 800 milliamps inside the cabinet “UNDER” 100 sq. ft. 5. LED options should be submitted for approval. 6. All electrical is to be UL approved. 7. Always engage professional engineering when determining the pole fabrication. The registered trademark symbol ® is to be included with the logo on all Pole Sign graphics. The symbol is to be located at the high edge of the “s” in Steakburgers as shown on the pole sign picture. Do not place “Drive Thru” words on logo section of the sign. Any “DRIVE THRU” sign cannot be stacked 2 separate lines. “DRIVE THRU” must be on the same line. The Freddy’s script needs to dominate other secondary signs such as “DRIVE THRU” SIGNAGE – POLE SIGN EXAMPLE SIGNAGE – POLE SIGN EXAMPLE SIGNAGE – POLE SIGN EXAMPLE Spread Footing Direct Burial Footing SIGNAGE – MONUMNET SIGN I. MONUMENT SIGN 1. Double face internally illuminated monument sign consisting of two cabinet signs with a reveal and an aluminum base. 2. Both cabinets signs are fabricated with .050 aluminum at minimum, sign company to ensure proper material thickness to prevent oil-canning. Skinned over angle-iron frames and painted to match PMS 186C. 3. Both cabinet faces have 1-1/2” retainers and 3/16” WHITE Lexan faces cut to size 4. Both cabinet faces have 3M 3630-033 RED translucent vinyl graphics applied to the first surface and are both illuminated by LED lamps powered by 800 milliamps inside the cabinet. Provide LED option. 5. UL label required. 6. Footing are the responsibility of the sign vendor and should be coordinated with the General Contractor. Most common method is a direct burial footing. 7. Brick on a sign vendor is typically the responsibility of the General Contractor. The registered trademark symbol ® is to be included with the logo on all Monument Sign graphics. The symbol is to be located at the high edge on the end of the “s” in Steakburgers as shown on the monument sign picture. SIGNAGE – MONUMENT SIGN EXAMPLE SIGNAGE – MONUMENT SIGN EXAMPLE SIGNAGE – MONUMENT SIGN EXAMPLE J. READER BOARD Reader Boards and or Digital Reader board requests must be approved by Freddy’s Construction Department and all manufacturers and suppliers are subject to review. 1. Preferred pixel matrix sizes for LED displays are 80x32, 144x40, 96x56, 112x48 and 128x64. 2. Larger sizes such as 224x64 will cost slightly more for art design. SIGNAGE – MULTI-TENANT K. MULTI-TENENT PANEL OPTIONS Option 1: Use ONLY on large Tenant Panel *This special logo or any variation CANNOT be used anywhere ON OR IN THE BUILDING and can ONLY be used WITHOUT THE CIRCLE CONE on a TENANT PANEL. Option 2: Use ONLY on a long Multi-Tenant panel or Tenant Panel not close to the store *This special logo or any variation including the circle cone by itself CANNOT be used anywhere ON OR IN THE BUILDING except for this application on a TENANT PANEL. Option 3: Use on a narrow Tenant Panel. Logo CANNOT be combined with circle cone *The special logo or any variation, including combing with the circle cone, CANNOT be used anywhere including ON OR IN THE BUILDING except for this application on a TENANT PANEL SIGNAGE – DIRECTIONAL SIGNS L. DIRECTION SIGNS 1. Double face internally illuminated directional sign fabricated of 1” angle iron frame. 2. Skinned with .050 aluminum at minimum, sign company to ensure proper material thickness to prevent oil- canning. Painted to match PMS 186C with a 1” red trim cap. 3. Face is WHITE acrylic with vinyl graphics applied to the first surface. 4. Illuminated with white LED, 7100K LED. 5. All electrical is to be UL approved. DIRECTIONAL SIGN #1 – Shape Logo Red Can, Red Background with White Lettering • Freddy’s Cone centered with shape outline • Trademark ® on Cone • Drive-Thru with fat arrow or Exit Only no arrow • Single White Shape Outline Border • With or Without Pole Cover • A white can and white acrylic face with red lettering is never an option with shape logo SIGANGE – DIRECTIONAL SIGNS DIRECTIONAL SIGN #2– Square Red Can, Red Acrylic with White Lettering • Freddy’s Logo, without Frozen Custard & Steakburgers • Trademark ® • Drive-Thru with fat arrow or Exit Only no arrow • Single Whie Outline Border • With or Without Pole Cover DIRECTIONAL SIGN #3 – Square Red Can, White Acrylic with Red Lettering • Freddy’s Logo, Without Frozen Custard & Steakburgers • Trademark ® • Drive-Thru with far arrow or Exit Only no arrow • No Outline Border • With or Without Pole Cover • Only is code requires white face can, this sign can be used SIGNAGE – INTERIOR FREDDY’S SIGN M. PREFERRED – Non-Illuminated Interior Freddy’s Sign 1. Fabricated from 3/4” PVC, waterjet, laser or CNC router cut to custom shape painted PMS 186 2. Layered 1/2” PVC, waterjet, laser or CNC router cut to custom shape painted White. 3. Whtie ½” PVC glued to red 3/4” PVC 4. (8) 1 1/2” x 3/8” bolts are to be countersunk into red 3/4” background, covered by white elements when attached 5. Bolts to be fastened to 1 1/2” x 1” angle aluminum with lock washers and nuts 6. Attach to wall by attaching 1 1/2” x 1” aluminum angle iron to drywall, using #12x1’ SDS into metal studs, then using #12x1” SDS to attach the display mounted angle to wall mounted angle 7. Provide 1 1/8” space of the wall SIGNAGE – INTERIOR FREDDY’S SIGN N. OPTIONAL – Illuminated LED Freddy’s Sign 1. 72” wide by 25” tall 2. 3/4” Routed Sintra Painted Red 3. White Vinyl Insert 4. Aurora Flex Mini Cool White