Burn BootcampTR
A
S
H
EXISTING TREES
FLAGSTONE WALKWAY
EXISTING TREES
10' CLEAR VISION TRIANGLE @ DRIVE ENTRANCES, TYP.
SNOW STORAGE AREA
4" CONCRETE CURB, TYP.
4" CONCRETE CURB, TYP.
4" CONCRETE CURB, TYP.
SN
O
W
S
T
O
R
A
G
E
A
R
E
A
GROUND COVERS
4,599 SF TURFGRASS SEED MIXSEED RATE: 3-4 LBS / 1000 SQ FT ------
1,380 SF PERENNIAL RYEGRASS SEED 30%
919 SF FINE FESCUE SEED 20%
2,300 SF KENTUCKY BLUEGRASS SEED 50%
5,373 SF PINE BARK MULCH ------
SHEET #
JOB #
DATE:
DRAWN BY:
L1
LANDSCAPE PLAN
D. Hunt
174
Bu
r
n
B
o
o
t
C
a
m
p
46
6
R
i
v
e
r
s
E
d
g
e
L
o
o
p
-Ka
l
i
s
p
e
l
l,
M
o
n
t
a
n
a
December 15, 2024
3/32" = 1'-0"1 LANDSCAPE PLAN
Planting Schedule
SYMBOL QTY BOTANICAL NAME COMMON NAME CONT.
SIZE SIZE
6 Ribes Alpinum Alpine Currant 5 Gal.
8 Festuca glauca Blue Fescue 1 Gal.
6 Forsythia x Intermedia Border Forsythia 5 Gal.
3 Picea pungens Colorado Spruce 15 Gal.B&B 2¼"CAL.
5 Cotoneaster acutifolius Cotoneaster 5 Gal.
10 Pennisetum Alopecuroides Dwarf Fountain Grass 1 Gal.
21 Calamagrostis acutiflora Feather Reed Grass 1 Gal.
11 Berberis Thunbergii Japanese Barberry 5 Gal.
46 Rosa Rugosa Japanese Rose 3 Gal.
10 Tilia Americana Linden, American 15 Gal.B&B 2¼"CAL.
11 Dasiphora fruticosa Potentilla 3 Gal.
3 Syringa x prestoniae Preston Hybrid Lilac 7 Gal.
1 Acer Saccharum Rock Maple 15 Gal.
B&B
2¼"
CAL.
21 Juniperus sabina Savin Juniper 3 Gal.
6 Spiraea Fritschiana Spiraea 5 Gal.
8'16'32'0
3"03/32" = 1'-0"
N
ROSE CROSSING
RI
V
E
R
S
E
D
G
E
L
O
O
P
*T.O. MULCH TO BE 1" BELOW SIDEWALK FINISHED GRADE
INTERIOR PARKING AREA (APPROX.)19,986 SF
INTERIOR PARKING AREA LANDSCAPING (APPROX.)1,610 SF
% OF INTERIOR PARKING LANDSCAPE 8.1 %
2' -
0
"
6' -
0
"
3X ROOTBALL DIA.
FINISHED GRADE
2"-4" HIGH SAUCER
MULCH, KEEP MIN. 4" FROM CROWN
SET TOP OF ROOTFLAIR WITHIN 1" OF FINAL GRADE, DO NOT COVER WITH SOIL.
(2) THREE INCH LODGE POLE PINE STAKES. INSTALL APPROXIMATELY 2" AWAY FROM THE EDGE OF THE ROOT BALL. STAKE LOCATION HALL NOT INTERFERE WITH PERMANENT BRANCHES.
32" LONG NON-ABRASIVE RUBBER TIES
REMOVE NURSERY STAKE. IF CENTRAL LEADER NEEDS TO BE STRAIGHTED OR HELD ERECT, IT IS ACCEPTABLE TO ATTACH A ½" X 8' BAMBOO POLE TO THE CENTRAL LEADER AND TRUNK
TREE & SHRUB PLANTING SOIL PER NOTES & SPECS
REMOVE ALL BURLAP, WIRE BASKET, AND TIES FROM ROOTBALL
PLACE ROOTBALL DIRECTLY ON UNEXCAVATED SOIL PEDESTAL TO PREVENT SETTLING
UNDISTURBED NATIVE SOIL
NOTES:1. ALL TREE PLANTINGS IN TURF AREAS SHALL BE IN A 5' DIA. MULCH RING2. ALL DECIDUOUS TREES SHALL RECIEVE A MIN. 4' HT "PLANTRA #TBCS0W-4800-0010" TRUNK PROTECTOR FOR PROTECTION FROM DEER
E Q EQGROUNDCOVER PLANTS TO BETRIANGULARLY SPACED.
MULCH
PAVEMENT
6"MIN
.
2"-3" LAYER OF MULCH
FINISHED GRADE
MODIFIED SOIL. DEPTH VARIES. (SEE SPECIFICATIONS FOR SOIL MODIFICATION).
EXISTING SOIL
NOTES:1. SEE PLANTING LEGEND FOR GROUNDCOVER SPECIES, SIZE, AND SPACING DIMENSION.2. SMALL ROOTS (¼" OR LESS) THAT GROW AROUND, UP, OR DOWN THE ROOT BALL PERIPHERY ARE CONSIDERED A NORMAL CONDITION IN CONTAINER PRODUCTION AND ARE ACCEPTABLE HOWEVER THEY SHOULD BE ELIMINATED AT THE TIME OF PLANTING. ROOTS ON THE PERIPERHY CAN BE REMOVED AT THE TIME OF PLANTING. (SEE ROOT BALL SHAVING CONTAINER DETAIL).3. SETTLE SOIL AROUND ROOT BALL OF EACH GROUNDCOVER PRIOR TO MULCHING.
PLAN VIEW
SECTION VIEW
2X ROOTBALL DIA.
FINISHED GRADE
2" HIGH SAUCER
MULCH, KEEP MIN. 4" FROM CROWN
SET TOP OF ROOTBALL 1"-2" ABOVE PLANTING SOIL GRADE
TREE & SHRUB PLANTING SOIL PER NOTES & SPECS
PLACE ROOTBALL DIRECTLY ON UNEXCAVATED SOIL PEDESTAL TO
PREVENT SETTLING
UNDISTURBED NATIVE SOIL
0' -
3
"
NOTES:
1. INSTALLATION TO BE COMPLETED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS.2. NOT TO SCALE
*TOP OF EDGING TO BE NO MORE THAN ½" (12.7mm) ABOVE FINISH GRADE
*TOP OF STACK DESIGNED TO LOCK 1/2" (12.7mm) BELOW TOP OF EDGING
*COMPACT GRADE ADJACENT TO EDGING TO AVOID SETTLING
EDGING STAKE PER MFR'R
TURF
ALUMINUM EDGING
SHEET #
JOB #
DATE:
DRAWN BY:
L2
LANDSCAPE
DETAILS
D. Hunt
174
Bu
r
n
B
o
o
t
C
a
m
p
46
6
R
i
v
e
r
s
E
d
g
e
L
o
o
p
-Ka
l
i
s
p
e
l
l,
M
o
n
t
a
n
a
December 15, 2024
PLANTING NOTES:
1/2" = 1'-0"1 TREE PLANTING DETAIL
3/4" = 1'-0"2 GROUNDCOVER
1/2" = 1'-0"3 SHRUB PLANTING DETAIL
1/2" = 1'-0"4 ALUMINUM EDGING
1. LANDSCAPE CONTRACTOR SHALL FURNISH NURSERY-GROWN PLANTS TRUE TO GENUS, SPECIES, VARIETY, CULTIVAR, STEM FORM, AND OTHER FEATURES INDICATED IN PLANT SCHEDULE AND COMPLYING WITH ANSI Z60.1. PROVIDE WELL-SHAPED, FULLY BRANCHED, HEALTHY VIGOROUS STOCK, DENSELY FOLIATED WHEN IN LEAF AND FREE OF DISEASE, PESTS AND DEFECTS SUCH AS KNOTS, SUN SCALD, INJURIES, ABRASIONS, AND DISFIGUREMENT.
2. IF ANY SPECIFIED SPECIES ARE UNAVAILABLE, THE LANDSCAPE CONTRACTOR SHALL
NOTIFY THE OWNER’S REPRESENTATIVE IMMEDIATELY. SUBSTITUTIONS SHALL ONLY BE MADE
UPON THE APPROVAL OF THE OWNER’S REPRESENTATIVE, OR LANDSCAPE DESIGNER. ALL CHANGES TO PLAN WILL REQUIRE PARK & RECREATION APPROVAL PRYOR TO PLANTING.
3. PLANTING SHALL OCCUR DURING THE SPRING (MAY 1 -JUNE 15) OR FALL (SEPTEMBER 15 -NOVEMBER 1) UNLESS OTHERWISE APPROVED BY THE OWNER'S REPRESENTATIVE OR LANDSCAPE DESIGNER. UNDER NO CIRCUMSTANCES SHALL PLANT MATERIALS BE INSTALLED WHEN AMBIENT TEMPERATURES EXCEED 90˚F.
4. LANDSCAPE CONTRACTOR SHALL PROVIDE THE LANDSCAPE DESIGNER WITH A PLANTING
SCHEDULE (1) WEEK PRIOR TO COMMENCING WORK. A PRE-INSTALLATION ON-SITE MEETING
WILL THEN BE SCHEDULED TO DISCUSS ANY SITE-SPECIFIC CONCERNS AND GENERAL PLANT LAYOUT.
5. ALL PLANT MATERIAL SHALL BE INSPECTED AND APPROVED BY THE OWNER’S REPRESENTATIVE PRIOR TO PLANTING. PLANT MATERIAL THAT HAS BEEN APPROVED FOR INSTALLATION SHALL BE PLANTED WITHIN 24 HOURS. PLANT MATERIAL THAT CANNOT BE PLANTED WITHIN ONE DAY FOLLOWING ARRIVAL SHALL BE HEELED-IN, KEPT MOIST AND PROTECTED AT ALL TIMES FROM EXTREME WEATHER CONDITIONS. PLANTS SHALL BE STORED AT THE SOLE RESPONSIBILITY OF THE CONTRACTOR.
6. THE LANDSCAPE CONTRACTOR SHALL DELIVER, MAINTAIN AND WATER ALL PLANT
MATERIALS THOROUGHLY WHEN PLANTED AND UNTIL OWNER’S FINAL ACCEPTANCE IS RECEIVED.
7. IF A DISCREPANCY EXISTS BETWEEN THE PLANT QUANTITIES ON THE PLANT SCHEDULE AND THOSE SHOWN ON THE PLAN, THE QUANTITIES ON THE PLAN SHALL PREVAIL.
8. SEEDED AREAS MUST BE PROTECTED BY A BARRIER WITH VISIBLE SIGNS THAT READ “KEEP OFF NEWLY SEEDED LAWN AREA”.
9. TREES SHALL NOT BE PLANTED WITHIN 10’FEET OF WATER OR SEWER LINES, WHERE
ROOTS COULD DAMAGE SIDEWALKS OR CURBING, OR IN LOCATIONS THAT COULD OBSTRUCT
STREET LIGHTING, SIGNAGE, OR GENERALLY RESULT IN A SAFETY CONCERN.
10. TREES SHALL BE SYMMETRICAL AND UNIFORM IN APPEARANCE, SIZE, AND STRUCTURE. SUNSCALED PROTECTION SHALL BE PLACED AROUND ALL TREES.
11.LANDSCAPE CONTRACTOR SHALL PROVIDE A WARRANTY PERIOD OF TWO (2) YEARS FROM DATE OF SUBSTANTIAL COMPLETION. WARRANTY SHALL INCLUDE REPLACEMENT OF PLANTINGS THAT ARE DEAD, DYING, DISEASED, LOST MORE THAN 30% OF IT’S NORMAL
FOLIAGE, AND BROKEN EXCEPT FOR INCIDENTS BEYOND THE CONTRACTOR'S CONTROL (LACK
OF MAINTENANCE BY OWNER, WEATHER RELATED SUCH AS BLOWING OVER, ETC.).
12. A CITY OF KALISPELL TREE PERMIT IS REQUIRED TO PLANT TREES WITHIN THE CITY R.O.W.
TR
A
S
H
ZONE 3
ZONE 4
ZONE 4
ZONE 3 ZONE 4
ZONE 4
ZONE 4
ZONE 4
ZONE 1
ZONE 2
ZONE 2
Z2
Z1
Z3
Z4
1"
1"
1"1"
POC
1"
1"
1"
1"
1"
ZONE 3
ZONE 3
ZONE 3
1"
1½"1"
IRRIGATION SCHEDULE
HUNTER MP-1000-90 PROS-04-PRS40MP ROTATOR NOZZLE, 0.4 IN/HR PRECIPITATION RATE, 8' TO 15' RADIUS, 90° TO 210° ADJUSTABLE ARC, FEMALE THREAD, MAROON
54
1
2
2
2
956 LF
20 LF
111 LF
HUNTER PGV-100-GPGV VALVE, SCREW-TOP, 1" VALVE WITH FEMALE THREAD INLET/OUTLET; NO FLOW CONTROL
HUNTER PCZ-101-25PCZ DRIP CONTROL ZONE KIT, 1" X ¾", 25 PSI REGULATION, 0.5 TO 15GPM
PIPE TRANSITION, ABOVE GRADEPIPE TRANSITION FROM PVC LATERAL LINE TO DRIP TUBING W/ RISER
IRRIGATION LATERAL LINE 1"1" POLYETHYLENE PIPE
IRRIGATION MAINLINE 1½"1½" SCHEDULE 40 PVC
4" SCHEDULE 40 PVC SLEEVE
40
40
--
--
--
--
--
--
5,163 SF
AREA TO RECIEVE DRIP EMITTERSHUNTER HE-BPOINT SOURCE DRIP EMITTERS W/ SELF-PIERCING 1/4" BARB, COLOR CODED FOR FLOW RATES OF: 0.5, 1.0, 2.0, 4.0, 6.0 GPH.CAN BE INSERTED INTO ½" & ¾" TUBING. PRESSURE COMPENSATION FROM 20-50PSI. OPTIONAL DIFFUSER CAP AVAILABLE (HE-DIFF)
20
EMITTER NOTES:
MANUFACTURER / MODEL / DESCRIPTION QTY PSISYMBOL
7820 EMITTERS (2 ASSIGNED TO EA. 1 GAL. PLANT)
6840 EMITTERS (2 ASSIGNED TO EA. 5 GAL. PLANT)
940 EMITTERS (3 ASSIGNED TO EA. 7 GAL. PLANT)
5660 EMITTERS (4 ASSIGNED TO EA. 15 GAL. PLANT)
9,763 SFIRRIGATION ZONES --
HUNTER X2-800-WAND8-STATION, WI-FI CAPABLE, 3 INDEPENDENT PROGRAMS, 120V
1
ZONE NOTES:
2,980 SFZONE 1
1,620 SFZONE 2
2,637 SFZONE 3
2,526 SFZONE 4
HUNTER MP-1000-210 PROS-04-PRS40MP ROTATOR NOZZLE, 0.4 IN/HR PRECIPITATION RATE, 8' TO 15' RADIUS, 210° TO 270° ADJUSTABLE ARC, FEMALE THREAD, LIGHT BLUE
23410 EMITTERS (3 ASSIGNED TO EA. 3 GAL. PLANT)
ZURN MODEL 720ABACKFLOW PREVENTER, UP TO 150 PSI
1
--
--
SHEET #
JOB #
DATE:
DRAWN BY:
L3
IRRIGATION PLAN
D. Hunt
174
Bu
r
n
B
o
o
t
C
a
m
p
46
6
R
i
v
e
r
s
E
d
g
e
L
o
o
p
-Ka
l
i
s
p
e
l
l,
M
o
n
t
a
n
a
December 15, 2024
3/32" = 1'-0"1 IRRIGATION PLAN
8'16'32'0
3"03/32" = 1'-0"
N
ROSE CROSSING
RI
V
E
R
S
E
D
G
E
L
O
O
P
MAIN LINE & FITTINGS
STANDARD VALVE BOX
DRIP ZONE KIT: MODEL PCZ-101-1 FILTER, REGULATOR 25 OR 40 PSI
SCH 80 T.O.E. NIPPLE
PVC SLIP UNIONS
¾" MINUS WASHED GRAVEL
(4) BRICK SUPPORTS
18-24" COILED WIRE
(2) WATERPROOF CONNECTORS
FINISHED GRADE -1" BELOW BOX FINISHED GRADE
LATERAL PIPE PER PLAN
LATERAL TEE OR ELL
SWING JOINT:FLEX TUBING, ELBOWS(2) & MARLEX STREET ELBOW(1)
SPRAY BODY PER PLAN
SPRAY NOZZLE PER PLAN
FINISHED GRADE
TOPSOIL
STAINLESS STEEL
SCREW CLAMP
#6 X 48" REBAR
QUICK COUPLER VALVE
REMOVED SOIL FOR DEBRIS -FREE VALVE
CAP OPERATION
SWING JOINT
TEE OR ELBOW
MAINLINE
DO NOT EXCEED 45°
22°45°
FLUSH
7½" [19 cm]OPEN DOOR WIDTH
4
1
2
5
3
IRRIGATION CONTROLLER (X2) PER PLAN
IRRIGATION CONTROL WIRE IN CONDUIT.SIZE AND TYPE PER LOCAL CODES.
ELECTRICAL PLUG AND CABLE
ADJACENT SURFACE TO MOUNTCONTROLLER PER PLAN
SMART PORT
1
2
3
4
5
1. SPECIFY 4, 6, 8, OR 14 STATION MODEL CONTROLLER.2. MOUNT CONTROLLER WITH LCD SCREEN AT EYE LEVEL.3. INSTALL SMART PORT APPROX. 12"[30cm] BELOW THE CONTROLLER TO ALLOW CLEARANCE FOR REMOTE CONTROL ANTENNA.
DETAIL LEGEND:NOTES:
1. SIZE PIPE AND FITTINGS PER MAINLINE.2. ALL ASSEMBLY PARTS (THREADED NIPPLES, FITTINGS, ETC.) SHALL BE COPPER OR BRONZE PER LOCAL CODES AND REQUIREMENTS.3. GALVANIZED NIPPLE SHALL EXTEND 12" PAST THE EDGE OF THE CONCRETE FOOTING.4. SCH. 80 PVC MALE ADAPTER SHALL BE USED IN CONNECTION FROM GALVANIZE TO THE MAINLINE.5. BACKFLOW PREVENTION DEVICE SHALL BE LOCATED AS CLOSE AS POSSIBLE TO THE LANDSCAPE METER.6. BACKFLOW PREVENTION DEVICE SHALL BE LOCATED IN PLANTING AREA UNLESS APPROVED BY OWNER'S REPRESENTATIVE.7. ALL BACKFLOW PREVENTION DEVICES SHALL HAVE FREEZE BLANKET INCLUDED UPON INSTALLATION.8. ALL SCH. 80 PVC TO COPPER CONNECTIONS TO BE MADE USING TEFLON TAPE.
NOTES:
12" CLR
SIDE VIEW
FRONT VIEW
FINISHED GRADE
EXTERIOR HOUSE WALL
BACKFLOW PREVENTION DEVICE PER PLAN
12"
BACKFLOW PREVENTION DEVICE:ZURN MODEL 720AINSTALL DEVICE PER LOCAL WATER PURVEYOR'S STANDARDS AND SPECIFICATIONS
CONNECTION TO EXISTING STOP AND WASTE VALVE
COPPER MALE ADAPTER
FINISHED GRADE
DE
P
T
H
(
T
Y
P
.
)
SE
E
P
I
P
E
T
R
E
N
C
H
DE
T
A
I
L
F
O
R
P
I
P
E
BRASS BALL VALVE
COPPER MALE ADAPTER
FLOW
WRAP 20 MIL TAPE TWICE AROUND ALL COPPER PIPE UNDER FINISHED GRADE AND THROUGH CONCRETE
COPPER PIPE
COPPER ELBOW
12" MIN. ABOVE HIGHEST HEAD
COPPER TEE
COPPER ELBOW
COPPER FEMALE ADAPTER
CONCRETE THRUST BLOCKS REQ'D ON
BACKFLOW DEVICES
2½" AND LARGER TRANSITION UNION MAINLINE X MHP
12
"
M
I
N
.
C
L
R
1" QUICK COUPLER FOR WINTERIZATION BLOWOUT
SHEET #
JOB #
DATE:
DRAWN BY:
L4
IRRIGATION
DETAILS
D. Hunt
174
Bu
r
n
B
o
o
t
C
a
m
p
46
6
R
i
v
e
r
s
E
d
g
e
L
o
o
p
-Ka
l
i
s
p
e
l
l,
M
o
n
t
a
n
a
December 15, 2024
IRRIGATION NOTES:
1" = 1'-0"1 PCZ-101 DRIP ZONE KIT
3" = 1'-0"2 SPRAY HEAD W/ FLEX TUBING
1" = 1'-0"3 QUICK COUPLER
3" = 1'-0"4 X2-800 CONTROLLER
3/4" = 1'-0"5 POC BACKFLOW ASSEMBLY
1.ALL NEW LANDSCAPE AREAS SHALL HAVE AN AUTOMATICALLY CONTROLLED IRRIGATION SYSTEM PER THE DRAWINGS. IRRIGATION SYSTEM WORK INCLUDES EXCAVATING, BACKFILLING, SUPPLYING AND INSTALLING ELECTRONIC CONTROLLER, VALVES AND FITTINGS, PIPING AND FITTINGS, QUICK COUPLER VALVES, VALVE BOXES, ACCESSORIES, TESTING, WINTERIZING AND SPRING START UP, AND INSTALLING/COORDINATING TEMPORARY IRRIGATION AS NEEDED.
2.OWNER WILL OBTAIN ALL PERMITS AND PAY ALL FEES TO ANY GOVERNMENTAL AGENCY HAVING JURISDICTION OVER THE WORK. IRRIGATION CONTRACTOR
TO INSTALL SYSTEM TO MEET ALL APPLICABLE CODES AND ARRANGE FOR INSPECTIONS, TESTING, AND CERTIFICATIONS IF REQUIRED
3.THE IRRIGATION SYSTEM HAS BEEN DESIGNED FOR A MAXIMUM FLOW OF 18 GPM AT A STATIC PRESSURE OF 60 PSI. IF AVAILABLE FLOW IS LOWER THAN 18 GPM OR PSI IS LOWER THAN 60 PSI, IRRIGATION CONTRACTOR SHALL CONTACT OWNER’S REPRESENTATIVE AND LANDSCAPE DESIGNER PRIOR TO CONSTRUCTION FOR SYSTEM DESIGN ADJUSTMENT. CITY OF KALISPELL WIIL NEED TO APPROVE ANY REVISION TO IRRIGATION PLAN PRIOR TO INSTALLATION.
4.THE IRRIGATION PLAN IS DIAGRAMMATIC. INSTALL MAINLINE, VALVES, PIPE, AND ASSOCIATED EQUIPMENT IN APPROXIMATE LOCATIONS SHOWN. MINOR ADJUSTMENTS IN SYSTEM LAYOUT WILL BE PERMITTED TO CLEAR EXISTING FIXED OBSTRUCTIONS.
5.LOCATE ALL ABOVE AND BELOW GROUND UTILITIES AND PROTECT THEM FROM DAMAGE DURING CONSTRUCTION. LANDSCAPE CONTRACTOR IS
RESPONSIBLE FOR ANY DAMAGE INCURRED DURING, OR AS A RESULT OF, CONSTRUCTION OF IRRIGATION SYSTEM.
6.TRENCHES SHALL BE EXCAVATED FOR ALL PIPE TO PROVIDE A MINIMUM DEPTH OF COVER BELOW FINISH GRADE OF 18”FOR MAIN LINES AND 12”FOR
LATERALS AND ALL OTHERS. ALLOW ENOUGH WIDTH FOR MINIMUM 3”BETWEEN PARALLEL PVC LINES. TRENCH BOTTOMS SHALL BE FLAT AND CLEAN OF ANY LARGE OR SHARP ROCK. EXERCISE CARE WHEN EXCAVATING TRENCHES NEAR EXISTING TREES.
7.INSTALL ALL MATERIALS AND EQUIPMENT IN STRICT ACCORDANCE WITH MANUFACTURER’S WRITTEN SPECIFICATIONS AND RECOMMENDATIONS.
8.PROVIDE ONLY NEW MATERIALS, WITHOUT FLAWS OR DEFECTS AND OF THE HIGHEST QUALITY OF THEIR SPECIFIED CLASS.
A. PVC MAINLINE SHALL BE CONSTRUCTED OF SCH. 40 PVC. LATERAL PIPE SHALL BE CONSTRUCTED
OF POLYETHYLENE PIPE. ALL PIPES SHALL BE PERMANENTLY PRINTED WITH STANDARD PERTINENT
INFORMATION.
B.PVC FITTINGS SHALL BE SCHEDULE 80 RATED FOR MAINLINE AND MEET ASTM D2466 STANDARDS \AND SPECIFICATIONS.C.PVC NIPPLES SHALL BE SCHEDULE 80 RATED AND MEET ASTM D1785 REQUIREMENTS AND SPECIFICATIONS. ALL NIPPLES WILL HAVE TAPERED THREADS.D.JOINING MATERIALS USED SHALL BE MANUFACTURED BY I.P.S. OR APPROVED EQUIVALENT, AND SHALL BE USED IN ACCORDANCE WITH THE MANUFACTURER’S WRITTEN SPECIFICATIONS AND SAFETY RECOMMENDATIONS.E.THREADED CONNECTIONS (PVC) SHALL BE SEALED WITH TEFLON TAPE OR TEFLON PASTE.
F.CONTROLLER SHALL BE 8-STATION MOUNTED IN A PLASTIC CABINET. INSTALLATION SHALL BE IN
G.ALL IRRIGATION WIRING TO BE “MULTISTRAND”WIRING.
9.SLEEVING:
A.IT SHALL BE THE IRRIGATION CONTRACTOR’S RESPONSIBILITY TO COORDINATE INSTALLATION OFIRRIGATION SLEEVES WITH THE GENERAL CONTRACTOR.B.IRRIGATION SLEEVES SHALL BE SCHEDULE 40 PVC, CONFORMING TO ASTM D 1785, AND SIZED AS SHOWN ON PLANS.C.CAP SLEEVE ENDS TO KEEP SLEEVES FREE OF SOIL AND DEBRIS.D.FLAG SLEEVE LOCATIONS WITH STAKES OR REBAR TO IDENTIFY SLEEVING LOCATIONS.
E.SOLVENT WELD ALL PIPE SLEEVE FITTINGS.
F.IRRIGATION PLAN INDICATES ALL REQUIRED SLEEVING FOR IRRIGATION SYSTEM ONLY.
COORDINATE WITH OTHER TRADES FOR ADDITIONAL REQUIRED SLEEVING FOR OTHER UTILITIES OR SERVICES.G.INSTALL IRRIGATION SLEEVES IN SAME TRENCH WITH ELECTRICAL CONDUIT WHERE FEASIBLE.
10.NO SUBSTITUTIONS WILL BE PERMITTED WHICH HAVE NOT BEEN SUBMITTED FOR PRIOR WRITTEN APPROVAL AND APPROVED BY THE CITY OF KALISPELL.
11.ANY IRRIGATION RE-DESIGN WORK OR SHOP DRAWINGS SHALL BE REVIEWED AND APPROVED BY THE OWNER’S REPRESENTATIVE PRIOR TO CONSTRUCTION. DRAWINGS MUST BE NEATLY DRAFTED AND INCLUDE ALL NECESSARY INFORMATION FOR A COMPLETE DESIGN REVIEW.
12.THE IRRIGATION CONTRACTOR IS RESPONSIBLE FOR ALL DAMAGES TO THE GROUNDS, WALKS, CURBS, ROADS, BUILDINGS, EXISTING VEGETATION, PIPING
SYSTEMS, ELECTRICAL SYSTEMS AND THEIR EQUIPMENT AND CONTENTS CAUSED BY LEAKS IN THE IRRIGATION SYSTEM BEING INSTALLED OR HAVING BEEN
INSTALLED. THE IRRIGATION CONTRACTOR SHALL REPAIR ALL DAMAGES AT THEIR EXPENSE AND IN A MANNER WHICH IS SATISFACTORY TO THE GENERAL CONTRACTOR AND THE OWNER.
13.UPON COMPLETION OF SYSTEM INSTALLATION, IRRIGATION CONTRACTOR SHALL OPERATE SYSTEM BY MEANS OF THE AUTOMATIC CONTROLLER INPRESENCE OF OWNER’S REPRESENTATIVE.
14.UPON ACCEPTANCE OF SYSTEM BY OWNER, THE IRRIGATION CONTRACTOR SHALL PROVIDE NECESSARY KEYS/OR OTHER TOOLS NECESSARY TO OPERATION; DRAIN; ACTIVATE SYSTEM AND SHALL SPEND SUFFICIENT TIME WITH OWNER TO ENSURE THAT SYSTEM OPERATION; MAINTENANCE; AND
WINTERING CAN CONTINUE ON AFTER THE DEPARTURE OF CONTRACTORS. THE IRRIGATION CONTRACTOR SHALL LABEL CIRCUITS CLEARLY ON CONTROLLER.
15.IRRIGATION CONTRACTOR SHALL PROVIDE IRRIGATION SYSTEM RECORD DRAWINGS LEGIBLY MARKED TO RECORD ACTUAL INSTALLATION WITHIN (30) DAYS
OF FINAL ACCEPTANCE. DRAWINGS SHALL INDICATE HORIZONTAL AND VERTICAL LOCATIONS OF ALL HEADS, LATERALS, MAINLINE, AND ALL OTHER IRRIGATION EQUIPMENT INSTALLED. IDENTIFY FIELD CHANGES OF DIMENSIONS AND DETAIL INCLUDING CHANGES MADE BY CHANGE ORDER. AN 11”X17”PLAN SHALL BE LAMINATED AND PLACED AT THE CONTROLLER LOCATION LEGIBLY SHOWING COLOR-CODED ZONES.
16.WINTERIZATION: IRRIGATION CONTRACTOR SHALL INSPECT SYSTEM, SHUTOFF AND DRAIN PIPE BETWEEN SHUTOFFS AND DOUBLE-CHECK VALVE AND BLOW OUT SYSTEM COMPLETELY BETWEEN SEPTEMBER 15 AND SEPTEMBER 30 DURING THE WARRANTY PERIOD FOR WINTERIZATION.
17.SPRING STARTUP: IRRIGATION CONTRACTOR SHALL INSPECT, PRESSURIZE SYSTEM, REPAIR LEAKS AND ANY FAULTY WORK, ADJUST AND PROGRAM
CONTROLLERS AS NECESSARY BEFORE APRIL 30 FOR SPRING STARTUP.
18.IRRIGATION CONTRACTOR SHALL GUARANTEE THE SATISFACTORY OPERATION OF EQUIPMENT, MATERIALS, AND WORKMANSHIP, INCLUDING THE RESTORATION OF THE AREA FOR A PERIOD OF ONE YEAR FROM THE DATE OF IT’S ACCEPTANCE. REPAIR OR REPLACE ANY DEFECT IN EQUIPMENT OR WORKMANSHIP OCCURRING WITHIN THAT YEAR PROMPTLY, UPON NOTIFICATION, AT CONTRACTOR’S EXPENSE.