KNTC Common Area Lift Station_4-15-24KNTC LIFT STATION
ARCHITECTURAL REVIEW
KALISPELL, MONTANA
KEY TEAM STILLWATER CORP. Owner DESIGN JACKOLA ENGINEERING & ARCHITECTURE, PC APRIL 15, 2024
KN
T
C
L
I
F
T
S
T
A
T
I
O
N
A
R
C
H
I
T
E
C
T
U
R
A
L
R
E
V
I
E
W
CONTENTS
SITE PHOTOS 3
LIFT STATION SITE PLAN 4
LIFT STATION LAYOUT 5
EXTERIOR ELEVATIONS WITH SURFACES 6
LIFT STATION SITE LANDSCAPE PLAN 7
LIFT STATION LANDSCAPE LEGEND 8
LIFT STATION COLORED LANDSCAPE PLAN 9
LIFT STATION ROOF PLAN 10
KN
T
C
L
I
F
T
S
T
A
T
I
O
N
A
R
C
H
I
T
E
C
T
U
R
A
L
R
E
V
I
E
W
1
KNTC AERIAL PHOTO COURTESY OF GOOGLE EARTH
VIEW TO THE EAST
VICINITY MAP PHOTO COURTESY OF GOOGLE EARTH
LIFT
STATION
VIEW TO THE NORTHWEST
SITE PHOTOS
SEE KNTC PH4 PLANS FOR
ROW IMPROVEMENTS
C2.001
C2.001
10
.
0
0
'
10
.
0
0
'
10.00'
C2.002
PUMP HOUSE
8"
H
D
P
E
2"
H
D
P
E
W
A
T
E
R
C2.003
R5
0
0
.
0
0
'
R80
0
.
0
0
'
3
2
R95.00'
R45.00
'
R50
.
0
0
'
3015 3016
3020
30
1
7
30
1
8
301
9
3021
30
1
5
30
1
2
30
1
3
30
1
4
301
6
3017
3018
3
0
1
9
3023
3024
302
2
3023
15.00'
6
3019.59
4
5
1
1
SUCTION LINES, IEIN 3013.0
LINCOLN ST
HIGHLINEDERMATOLO
G
Y
F.F. =3025.20'
o
o
o
o
o
o
o
o
o o
o
o
o o
o
oo
o
o
o
o
o
o
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SSSSSSSSSS
SS
SS
SS
SS
SSSSSS
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD SD
W
W
W
W
W
W
W
W
W
UP UP UP UP
W
W
W
W
(2)
8
"
H
D
P
E
(
1
S
U
C
T
I
O
N
,
1
PO
N
D
L
E
V
E
L
M
A
N
H
O
L
E
)
(1)
4
"
H
D
P
E
S
U
C
T
I
O
N
7
8
#KEYNOTES:
1. PATH WIDENING FOR PEDESTRIAN BENCH, TYP. COORDINATEBENCH MAKE AND MODEL WITH OWNER.2. NEW 6" STEEL CASED WELL FOR POND FILLING. WELL MUST BEINSTALLED BY LICENSED MT WELL CONTRACTOR.3. POND INLET PER 3/C1.41.
4. POND OUTLET PER DETAIL 3/C2.00.
5. POND WATERFALL PER DETAIL 3/C2.00.6. DRYWELL FOR DRAINING POND PER DETAIL 4/C2.00.
7. POND WATER LEVEL MANHOLE PER DETAIL 7/C2.008. WINTERIZATION DRYWELL PER DETAIL 8/C2.00
GENERAL NOTES:1. FOR FUTURE PEDESTRIAN PATH ELEMENTS ASSOCIATED WITH
CROSSING PLEASE REFERENCE THE PH4 SUBDIVISION PLANS.
2. PROVIDE MECHANICAL JOINT FITTINGS & THRUST BLOCKS ON
PVC WATER MAINS. USE FUSED HDPE FITTINGS ON SUCTION
LINE
C2.001
R8
0
0
.
0
0
'
R3
0
0
.
0
0
'
R6
0
0
.
0
0
'
30253024
DATE:
JACKOLA ENGR. & ARCH., P.C. WITHOUT THE WRITTEN CONSENT OFMAY NOT BE USED OR REPRODUCEDIS PROPRIETARY. THIS DOCUMENTTHE INFORMATION CONTAINED HEREIN
REVISIONS:
KALISPELL
406-755-3208
#
BOZEMAN
406-586-0707
VANCOUVER
360-852-8746
DRAWN:CHECKED:
info@jackola.com jackola.com
PR
O
J
E
C
T
#
:
Z:\
C
l
i
e
n
t
F
i
l
e
s
\
2
0
2
1
\
S
t
i
l
l
w
a
t
e
r
C
o
r
p
\
2
1
0
4
2
1
K
N
T
C
C
o
m
m
o
n
A
r
e
a
\
6
D
r
a
w
i
n
g
s
\
1
A
u
t
o
c
a
d
\
P
h
a
s
e
2
\
K
N
T
C
C
o
m
m
o
n
A
r
e
a
_
P
H
2
_
C
1
.
1
0
.
d
w
g
PERMIT SET
21
0
4
2
1
1/25/23
TLMWJS
DETAILED SITE
AND UTILITY
PLAN
KA
L
I
S
P
E
L
L
,
M
O
N
T
A
N
A
KA
L
I
S
P
E
L
L
N
O
R
T
H
T
O
W
N
C
E
N
T
E
R
KN
T
C
P
H
3
C
O
M
M
O
N
A
R
E
A
P
H
2
ST
I
L
L
W
A
T
E
R
C
O
R
P
O
R
A
T
I
O
N
DETAILED SITE & UTILITY POND PLAN11" = 30'15-15 30 60
SCALE: 1" =
0
30'PH4 TO JEFFERSON PATH EXTENSION21" = 30'15-15 30 60
SCALE: 1" =
0
30'
CITY COMMENTS 03/30/20231
1
1
1
2
REVISION 2 04/01/20242
2
LIFT STATION SITE PLAN
KN
T
C
L
I
F
T
S
T
A
T
I
O
N
A
R
C
H
I
T
E
C
T
U
R
A
L
R
E
V
I
E
W
2
NOT TO SCALE
KN
T
C
L
I
F
T
S
T
A
T
I
O
N
A
R
C
H
I
T
E
C
T
U
R
A
L
R
E
V
I
E
W
NOT TO SCALE
3
NOT TO SCALE
LIFT STATION LAYOUT
EXTERIOR ELEVATIONS WITH SURFACES
KN
T
C
L
I
F
T
S
T
A
T
I
O
N
A
R
C
H
I
T
E
C
T
U
R
A
L
R
E
V
I
E
W
4
SOUTH ELEVATIONNORTH ELEVATION
EAST ELEVATION WEST ELEVATION
IKO
CAMBRIDGE
DUAL BLACK
ASPHALT
SHINGLES
DOUBLE STEEL
DOOR
FIBER CEMENT
BOARD & BATT
CEDAR MILL
7” REVEAL
SHERWIN
WILLIAMS
BURNISHED BRANDY
SW7523
EXTERIOR
PAINT
DOOR, TRIM,
SOFFIT
EXTERIOR
SIDING
ROOF STEEL DOOR
PHILIPS
STONCO
327 SCONCE
FIBER CEMENT
PANEL VERTICAL
SIDING
CEDAR MILL
SHERWIN
WILLIAMS
IRON ORE
SW7069
EXTERIOR
SCONCE
EXTERIOR
SOFFIT
NOT TO SCALE
KN
T
C
L
I
F
T
S
T
A
T
I
O
N
A
R
C
H
I
T
E
C
T
U
R
A
L
R
E
V
I
E
W
CASCADE LOOP
LINCOLN ST
JE
F
F
E
R
S
O
N
B
O
U
L
E
V
A
R
D
CASCADE LOOP
HIGHLINEDERMATOLOG
Y
F.F. =3025.20'
o
o
o
o
o
o
o o
ooo
o
o
o
o
o
W
W
W
W
W
W W W
W
IRR
DFDF
DF
DF
DF
DFDF
DF
DFDFDF
SEE 1/C1.41
SEE 2/C1.41
SEE 4/C1.41
SEE 3/C1.41
4
4
4
4
DF
DF
DF
DATE:
JACKOLA ENGR. & ARCH., P.C. WITHOUT THE WRITTEN CONSENT OFMAY NOT BE USED OR REPRODUCEDIS PROPRIETARY. THIS DOCUMENTTHE INFORMATION CONTAINED HEREIN
REVISIONS:
KALISPELL
406-755-3208
#
BOZEMAN
406-586-0707
VANCOUVER
360-852-8746
DRAWN:CHECKED:
info@jackola.com jackola.com
PRO
J
E
C
T
#
:
Z:\C
l
i
e
n
t
F
i
l
e
s
\
2
0
2
1
\
S
t
i
l
l
w
a
t
e
r
C
o
r
p
\
2
1
0
4
2
1
K
N
T
C
C
o
m
m
o
n
A
r
e
a
\
6
D
r
a
w
i
n
g
s
\
1
A
u
t
o
c
a
d
\
P
h
a
s
e
2
\
K
N
T
C
C
o
m
m
o
n
A
r
e
a
_
P
H
2
_
C
1
.
4
0
.
d
w
g
PERMIT SET
210
4
2
1
01/25/2023
TLMEMS
OVERALL
LANDSCAPING
PLAN
KA
L
I
S
P
E
L
L
,
M
O
N
T
A
N
A
KA
L
I
S
P
E
L
L
N
O
R
T
H
T
O
W
N
C
E
N
T
E
R
KN
T
C
P
H
3
C
O
M
M
O
N
A
R
E
A
P
H
2
ST
I
L
L
W
A
T
E
R
C
O
R
P
O
R
A
T
I
O
N
OVERALL LANDSCAPING PLAN11" = 20'20-20 40 80
SCALE: 1" =
0
40'
CITY COMMENTS 03/30/20231
1
NOT TO SCALE
5LIFT STATION SITE LANDSCAPE PLAN
LIFT STATION LANDSCAPE LEGEND
KN
T
C
L
I
F
T
S
T
A
T
I
O
N
A
R
C
H
I
T
E
C
T
U
R
A
L
R
E
V
I
E
W
6
KN
T
C
L
I
F
T
S
T
A
T
I
O
N
A
R
C
H
I
T
E
C
T
U
R
A
L
R
E
V
I
E
W
7
NOT TO SCALE
LIFT STATION COLORED LANDSCAPE PLAN
!
"
#
#
$
!"#$%&'"(%)&"*+++++++$%&'"(%)&"*
, ,
-
+
.
/
/0 0 0 , 1+2+/0 1/ 3+
# % #%
& '
()!
/+/, 1+2+/0 1 + 4
/+/, 1+2+/0 1 + 4
#
*) + ,
/1+2+/0 1 3+ 33 + )
LIFT STATION ROOF PLAN
KN
T
C
L
I
F
T
S
T
A
T
I
O
N
A
R
C
H
I
T
E
C
T
U
R
A
L
R
E
V
I
E
W
8