Ordinance 1028 - Notice of Intent - Code Adoption0834
CITY OF KALISPELL
MONTANA
NOTICE OF INTENTION TO ADOPT BY REFERENCE THE "UNIFORM
BUILDING CODE, 1982 EDITION", "UNIFORM MECHANICAL CODE,
1982 EDITION", "UNIFORM HOUSING CODE, 1982 EDITION",
"UNIFORM PLUMBING CODE, 1982 EDITION", AND A "UNIFORM
CODE FOR ABATEMENT OF DANGEROUS BUILDINGS, 1982 EDITION";
AS AMENDED, ADOPTED AND APPROVED BY THE BUILDING CODES
DIVISION, DEPARTMENT OF ADMINISTRATION, STATE OF MONTANA.
NOTICE.IS HEREBY GIVEN, Pursuant to Section 7-5-108,
M.C.A. and 7-5-4202, M.C.A., that the City Council of
the City of Kalispell, Montana, did on the 21st day of
March, 1983, conduct a First Reading of Ordinance No.
1027 and Ordinance No. 1028 which were Ordinances
adopting the "Uniform Building Code", "Uniform Mech-
anical Code" and the "Uniform Code for Abatement of
Dangerous Buildings"; and the "Uniform Plumbing Code",
respectively; as said codes were amended, adopted and
approved by the Building Codes Division, Department of
Administration, State of Montana, in accordance with
Section 2.32.203, Administrative Rules of Montana.
Notice is further hereby given that the City Coun-
cil of the City of Kalispell, Montana, intends to
finally adopt, at Second Reading, the above referenced
codes on the 18th day of April, 1983, at the regular
meeting of the City Council at 7:30 P.M., in the Council
Chambers, City Hall, Kalispell, Montana.
Three copies of the above referenced codes to be
adopted together with the appendices adopted and the
amendments approved by the Building Codes Division,
shall be filed with the City Clerk of the City of Kal-
ispell for public inspection, use and examination
during regular business hours.
DONE BY ORDER OF THE CITY COUNCIL OF THE CITY OF
KALISPELL, MONTANA, THIS 21ST DAY OF MARCH, 1983.
PUBLISH:
Marj ie Giermann
City Clerk -Treasurer
l
1
4 8 5
ORDINANCE NO. 1028
AN ORDINANCE, TO ADOPT, BY REFERENCE, THE "UNIFORM PLUMBING CODE",
1982 EDITION, AS THE PLUMBING CODE OF THE CITY OF KALISPELL, AND
APPLICABLE TO THE JURISDICTIONAL AREA THEREOF; AS ADOPTED AND AP-
PROVED BY THE BUILDING CODES DIVISION, DEPARTMENT OF ADMINISTRATION,
STATE OF MONTANA; TO PROVIDE A PENALTY FOR THE VIOLATION OF ANY
LAWFUL ORDER ISSUED PURSUANT THERETO; AND REPEALING SECTION 21-1
(ORDINANCE NO. 946), KALISPELL CITY CODE.
Pursuant to the authority of the City of
provisions of Sections 7-5-108 and 7-S-4202,
by the City Council of the City of Kalispell,
Kalispell under the
M.C.A., be it ordained
Montana, as follows:
SECTION I. There is hereby adopted, by reference, the "Uniform
Plumbing Code", 1982 Edition, Library of Congress Catalog Card
Number 78-073977, by the International Association of Plumbing
and Mechanical Officials; said code is adopted in its entirety;
except for, and with the following amendments:
A) Asbestos -cement vent pipe is not an acceptable
material in the City of Kalispell for DWV, and
B) Homogenous bituminized fiberdrain and sewer pipe
is not acceptable material in the City of Kalispell,
except in drain .fields, and
C). Amend Section 20.5, Page 3a, Work not Requiring a
Permit, so that it then reads:
"No permit is required for any minor replacement
or repair work, the performance of which does not
have a significant Rotential for creating a con-
dition hazardous to public health and safety. The
rovisions of this act do notapply to regularly
employed maintenance personnel doing maintenance work
on the business premises of their employer unless
work is subject to the permit provisions of this act.
Factory -.built buildings covered by an insignia issued
by the Building Standards Bureau need not have a
plumbing 2ermit for the construction of the unit;
however, a permit will still be re uired for on site
work, as provided for in these rules.", and
D) Amend Section 20.7, Page 4a, Schedule of Fees, by
deleting lines 11 and 12 and substituting therefore:
"For each gas piping system of one (1) to four
(4) outlets ... $2.00,"
and
"For each gas piping system of five (5) or more,
per outlet ... $ .50,1-
E) Amend Section 203(a), Page 14, Use of Copper
Tubing, so that it then reads:
(a) Copper tube for underground drainage and vent
piping shall have a weight of not less than that
of copper drainage Type L.
F) Section 203(d), Page 14, Use of Copper Tubing,
so that it then reads:
(d) Copper tube for water piping shall have a
weight of not less than Type L. Exception: Type
M copper tubing may be used for water piping when
piping is above ground in, or on, a building.
t'336
G) Amend Section 401(a), Page 3/, Materials, item 2
by amending Section to read as follows:
(a) (1)
(2) ABS and PVC DWV piping installations
shall be limited to residential, commercial,
institutional and industrial construction
not more than two stories in height, provided
that ABS and PVC DWV ma be used for hori-
zontal branch lines re ardless of the number
of stories.", and
H) Amend Section 406(a), Page 40, Cleanouts so that it
then reads:
(a) "Each horizontal drainage pipe shall be
provided with a cleanout at its upper terminal
and each run of piping, which is more than one
hundred (100) feet (30.4m) in total developed
length, shall be provided with a cleanout for
each fifty (50) feet (15.2m) or fraction there-
of, in length of such piping. Lines six (6)
inches in size and larger shall be provided with
a cleanout for each one hundred (100) feet (30.4m)
or fraction thereof, in length of such piping.", and
i) Section 407, Page 41, Grade of Horizontal Drainage Piping
so that it then reads "Horizontal drainage piping shall be
run in a practical alignment and a uniform slope of not less
than one-fourth (4) of an inch per foot (20.9mm/m) or two
(2) per cent toward the point of disposal provided that,
where it is impractical due to the depth of the street and
sewer or to the structural features or to the arrangement
of any buildings or structures to obtain a slope of one-
fourth (4) of an inch per foot (20.9mm/m) or two (2) per
cent, any such pipe or piping two (2) inches (50.8mm) or
larger in diameter may have a slope of not less than one --
eighth (1/8) of an inch per foot (10.4mm/m) or one (1) per
cent, and
d) Amend Section 409(a), page 41, Drainage of Fixtures
Located Below the Next Upstream and Manhole or Below_ the
Main Sewer Level to read:
a) Drainage, piping, serving fixtures which have
flood level rims located below the elevation of the
next upstream manhole cover of the public sewer
serving such drainage, piping may be protected from
back flow of sewage by installing an approved type
back water valve. Fixtures above such elevation
shall not discharge through the back water valve, and
K) Amend Section 503(a), Page 45, Materials to read:
(a) (1)
(2). ABS and PVC DWV piping installations shall
be limited to residential, commercial, institu-
tional and industrial construction not more than
two stories in height, provided that ABS .and PVC
DWV may be used for horizontal branch lines re-
gardless of the number of stories, and
L) Amend Section 506(a) (c), Page 46 to 47, to read as
follows:
a) Each vent pipe ofl:stack shall be extended through
its flashing and shall terminate vertically not less
than twelve. (12) inches (304.8mm/m) above the roof
nor less than one (1) foot (.3m) from any vertical
surface, and
1
1
337
c) Vent pipe shall be extended separately or
combined, a full required size, not less than
twelve (12) inches (304.8mm/m) above the roof or
firewall. Flagpoling events is prohibited except
where the roof is used for purposes other than
weather protection. All events within ten (10)
feet (3m) of any part of the roof that is used
for such other purposes shall extend not less
than seven (7) feet (2.1m) above such roof and
shall be securely stayed, and
M) Amend Section 1004(a), Page 75, Materials to read as
follows:
a) Water pipe and fittings shall be of brass,
copper, cast iron, galvanized malleable iron,
galvanized wrought iron; galvanized steel, lead
or other approved materials. Asbestos -cement, PB,
PE or PVC water pipe manufactured to recognized
standards may be used for cold water distribution
systems outside a building, provided however, that
this same material may extend to a point immediately
inside the building when a sleeve for all pipe
ass.ing through or under concrete construction and
valve are provided at a point of entrance. PB
water pipe and tubing may be used for hot and cold
water distribution systems within a building. All
.materials used in the water supply system, except
valves and similar devices shall be of a like
material, except where otherwise approved by the
Administrative Authority, and
N) Amend Section 1008(3), Page 77, Installation and_ Inspec-
tion in Testing to read as follows:
(3) (f) Disinfection. When required by the
Administrative Authority having jurisdiction,
potable water systems or any part thereof in-
stalled or repaired shall be disinfected in
accordance with one of the following methods:
i) By filling the system or any part
thereof with a solution containing fifty
parts per million of available chlorine
and allowing it to stand for a minimum
period of six hours before flushing, or
ii) By filling the system or any part
thereof with a solution containing one
hundred parts per million of available
chlorine and allowing it to stand for a
minimum period of two hours before flush-
ing, or
iii) In the case of a potable water storage
tank where it is not possible to disinfect
by one of the above methods, the entire in-
terior of the tank shall be swabbed with a
solution containing two hundred parts per
million of available chlorine and allowing
it to stand two hours before flushing, or
iv) In the case of potable water filters
or similar equipment.; the mixture shall be
determined by the Administrative Authority
having jurisdiction.
O) Amend Section 1009(h), Page 79, Size of Potable Water
Piping to read as follows:
h) Knowing the available pressure at the
water meter or other source of supply, and
after subtracting one-half (�) pounds per
square inch pressure for each foot (11.3kPa
per. m) of.difference in elevation between
such source of supply and highest water supply
outlet in the building or on the premises, use
the "pressure range" group within which this
pressure will fall. Select the "length" column
which is equal to or longer than the required
length. Follow down the column to a fixture
unit valve equal to or greater than the total
number of fixture units required by the instal-
lation. Having located the proper fixture unit
for the required length, size of meter.and build-
ing supply pipe will be found in the two left hand
columns.
No building supply pipe shall be less than
three-quarter 13/4) inch (19.1mm) in inside
diameter.
P) Amend Section 1106(a), Page 86 to 87, Grade,
Support and Protection of Building Sewers to read as
follows:
(a) Building sewers shall be run in practical
alignment and at a uniform slope of not less
than 4 (one -quarter) of an inch per foot (20.9 _.
mm per m) toward the point of disposal; provided
that where it is impractical, due to the depth
of the street sewer or to the structural features
or to the arrangement of any building or structure,
to obtain a slope of 4 (one -quarter) of an inch
per foot (20.9 mm per m), any such pipe or piping
three (3) inches (76.2 mm) or larger may have a
slope of -not less than 1/8 (one -eighth) of an
inch per foot (10.5 mm per m), when approved by
the Administrative Authority.
At least three copies of said documents shall be kept on file
in the office of the City Clerk for inspection by the public.
Q) Appendix E, Mobile Home Parks, Page 163-175; delete.
R) Appendix G, Swimming Polls, Page 176-177; delete.
S) Amend Appendix C, Minimum.Plumbing Facilities, Page
151-154 so that it reads as follows:
.. . - i11rJD M REQUIRED FURfB= Fi7C ME 3,7 -
DrIn4in,F
Rlcwpaney
Water Closets
Urinals
iava`orles3
Fouutaira
Pala Ferale
Male
Flx urea&ersons
FSxtureslFlox�
.. .. --
FixtureslYersrma
or Wilding
Crcupa'0.-1, A-2, M2.1, A-i
1 1-150 .' 1 1-140
_. 1 $1-21J05
Ose Sectlon 605 of
Use Section [r?'s or
4 A-4 and ShoppLng Cen rs-
2 151QMO :' 2 101-150
2 201-401i'
tie Undone Euilllre
the Untrors Suildinq
and Assembly Buildluga�
3 201-400 "3 151-4W -
3 401.600
'Cade
Gods
4 Qi_WO 4 401-600
Over fi00. add 1
Add 1 fixture for each ad-
rat -each additional
s
ditional 500 ralles and 1 for
300 tales
_.
ea,:h 30D Bales
-
-
Croups E-1, E•+2 b F.-3 .
For elaw ntary and secondary school plumbing fixtures use Section 805 of the
uniform Fruild!nq Code.
Schools
1:100 1:60 1:100 1T230
VFioor or Building
Caliegen 6 Universittes
1.20 1:20 over 20: may sub- 1:60 -
llFloor or6Building
Day Caro
May to+hire MIS and female stitute for I r=ber
plus d:100 ,
unless fixture requirmwnt or toile-5 requlred
exceeds 2'
Croups I-1. I-2
Jails, Frieons, Detention
One water closet and one lavatory for each cell. One additional
,
Units
water closet and lava" for every eight in ndtiple occupancy
cells. One short-r fa. every Ciiteen.
Hospitals and Hureing uoma
See Title 16, Chapter 32. Admiutatrative R9les of lxe*ana '
Rurseries -
See Section 1205 of the Uniform Building Code. •
1iFloor or Building
Croups H-1, M-2, H-3, 11-4.
Use :victim yo5 aM 705 of the Unlform Building Core Car employees. -
R-5 R-1. 04. B-3, 6 DA
Office, stores, service
Toilet facilities for the public are to Ee p-aided as noted for
stations, public buildings-
Groups A and S and ebopping centers arid, in a.!tlitix. where
'
,food aefvlces facilities
alcoholic beverages are sold for on -site eonsr_-pticn, add to
the fixture requireffemts 1 extra urinal Cor ral=c from 1-IOO;
2 from 101-3W; ] f^an 301-600; 1 per 300 ever 500 and 1 extra
'
_
water closet for females :Yon 51-25D; 2 extra Cron 151-400 and
.
I per.15U Over 400. Kandwashing sinxs are required in all -
'
food preparation areas.4 .
Groups R-I.
Hotels, Apartments. totals,
Use Section 1295 or the Uniform building Cade.
C:vmts and Monasteries
-
Group I It-3
Dwelling and Lodging Horses
Use Sectlop,2205 of the Uniform tuildmg Code.
1 'Required plumbtn3 fixtures may be provided as separated employee and public.toil9Ls or as public toilRts with employee
- accessibility. -
2 Keyed Toilets under employee control of the type available at service s*atitrs awre permitted.
3 Rot and Cold Water required.
4 Contact the Department oC Peaith and Environmental Sciences for additional ragulm-.-nts for food service estabIbhr"1A.
6 Unless alternate-provl3lors af�Cep3rtnent or Health -and �Fxrvlrorurental Sclence3 are used.
! 7 When calcutating nunber of male acd revileant occups, the occupant load of tea building shall be comidared half vale
Pr.d hatr regale, and the cccepant lopd shall be calculated In accordance with Sec. 3301(d) bf the Uniform Building
{, Or,de.
1
389
T) Appendix I, Private Sewage Disposal Systems, Page
180-194; delete.
SECTION II. Compliance with Uniform plumbing Code; License;
Bond. All plumbing work done within the City shall conform to
the rules, regulations and requirements described and defined
in the Uniform Plumbing Code, and shall be inspected and ap-
proved in the manner therein set forth;
A) All work of plumbing and drainage shall be.
performed by a Journeyman plumber, duly licensed
hereunder as such, and under the supervision of
an employing or Master Plumber duly licensed and
bonded as such as herein provided; provided, that
such licensure and supervision.shall not be re-
quired in those instances setforth in Section
37-69-102, M.C.A. A change in plumbing and drainage
system shall be governed by the same rules applying
to any work.
B) A person engaged in the business of plumbing in the
City, either as a Master or as a Journeyman Plumber,
rescribed by Section
shall first secure a license, as p
37-69-301, M.C.A.; and in addition thereto must first
obtain a license from the City Clerk -Treasurer at the
following rates:
i) Master Plumber's License, twenty-five dollars
($25.00) per year or any fraction thereof.
ii) Journeyman Plumber's License, five dollars
($5.00) per year or any fraction thereof.
All such licenses so issued by the City Clerk -Treasurer
shall expire December 31 of each year, and shall be -e-
newed annually at the time prior to expiration, upon
payment of $10.00 for each Master Plumber's License and
$5.00 for each Journeyman Plumber's License. Any
ifsuch
renewal shall be for a period of one (1) year.
the
license granted and issued to a Master or Journeyman
Plumber by the Board of'Plumbers shall be suspended or
revoked by the Board of Plumbers, such action shall also
constitute a similar suspension or revocation of the license
granted to such person by the City of Kalispell. Also,
the City Council of the City of Kalispell may, upon good
cause shown and after affording such licensee a fair hearing.,
revoke or suspend any City license granted and issued here-
under. Willfull violation ofany
of the
eeprovisions
gof the
a shall be
plumbing code of the city by Y l
cause for such a suspension or revocation.
C) No person shall engage in the business of plumbing
under a Master Plumber's License without first obtaining
and furnishing to the City a public liability bond in
the sum of one thousand dollars ($1,000.00), approved
as to form and sufficiency by the City Council and con-
dition that such person will, in good faith, perform
all the things required of him by they nifordamage Code and that if any injury to any p
any property results by reason of his failure or neglect
to conform with this chapter, he shall save harmless and
indemnify such person injured or the owner of such pro-
perty damaged:
SECTION III. It is unlawful for any person to knowingly, pur-
posely, willfully or negligently violate any lawful order is-
sued pursuant to said Uniform Plumbing Code; such a violation
is an offense against the City punishable as provided by
Section 1-9.0f the Kalispell City Code.
3 4 0
SECTION IV. Section 2-1, Kalispell City Code (Ordinance No.
946) is hereby repealed and all other Ordinances, or parts
thereof of the City in conflict herewith are hereby repealed.
SECTION V. This Ordinance is effective thirty (30) days
following final approval by the Council and the Mayor and
the filing with the City Clerk of the prescribed copies of
the code hereby adopted by reference.
FINALLY PASSED BY THE CITY COUNCIL OF THE CITY OF KALISPELL AND AP-
PROVED BY THE MAYOR THIS DAY OF
1983.
R -E- .-McDowell , Mayor
ATTEST:
MarjoT'Giermann, City Clerk -Treasurer
I. Marjorie Giermann City Clerk of the City of Kalispell, Montana, do certify that on
the � day of - � 19 g-3 I
~f__ , posted a copy of the foregOing ordinance
zn my of i-ce and th same remained posted until the second reading
and the foregoing an the��d of
19 3 ` gongs a true and cgr�ect copy of the ordinance
as passe by the City Council, i'
City Clerk of the City of Kalispell, Montana
1
1