Resolution 3646 - Design and Construction StandardsRESOLUTION NO. 3646
A RESOLUTION TO AMEND RESOLUTION NO 3396 , BY AMENDING THE STANDARDS
AND GENERAL PROVISIONS FOR DESIGN AND CONSTRUCTION FOR THE CITY OF
KALISPELL, MONTANA.
WHEREAS, the City of Kalispell adopted on the' 15th day of March,
1982, pursuant to Ordinance No. 1003, the "Standards and General
Provisions for Design and Construction," City of Kalispell , Montana,
and
WHEREAS, it has become necessary to amend and correct the "Standards-....
�# . �!�. al�l
and General Provisions for the Design and Construe Vfo'n" for the eff;Fcientlqr�
operation of the City of Kalispell Public Works.
f. NOW THEREFORE, BE IT RESOLVED BY THE �ITY COUNCIL OF THE CITY OF
KALISPELL THAT THE STANDARDS AND GENERAL PROVISIONS FOR DESIGN AND
CONSTRUCTION OF THE CITY OF KALISPELL, MONTANA, ARE AMENDED AS FOLLOWS:
SECTION 1. As set forth in Exhibit "A" attached hereto and
thereby made a part hereof.
SECT -ION II. This Resolution shall become effective immediately
upon passage by the City Council and approval by the Mayor.
PASSED AND APPROVED BY THE CITY COUNCIL OF THE CITY OF KALISPELL
AND APPROVED BY THE MAYOR THIS 7th DAY OF APRIL, 1986.
VAhn "Ed" Kennedy Jr'.t Mayor
ATTEST:
City Clerk -Treasurer
I, the undersigned, City Clerk of the City of Kalispell, certify that the foregoing
is a true copy of the Resolution passed by the City Council of the City of Kalispell,
Montana, at a regular meeting held
City Clerk of the City of Kalispell, Montana
EXHIBIT "A"
Page 1-1 GP-03 City Fees
Sewer Service Connection Fee.
Change "Construction In/To Public Facilities" to "or before
the utility excavation"
Page 1-2 GP-04
Change title "Construction in/to Public Facilities Permit"
to "Utility Excavation Permit and Public Right of Way Improve-
ment Permit"
Under the new ti6e add the following paragraph:
1. Utility Fxcavation Permit. All work affecting
underground utility improvements -requires an utility
excavation permit approved by the Director of Public
Works or hi� authorized representative. The permit
will not be �approved -until all licensing, insurance
and bonding �irequirements have been met and necessary
fees paid. Utility excavation permits are required
for:
In the paragraphs Water Tap and Sanitary Sewer Connection
change "ConstructIon in/to Public Facilities Permit" to
"Utility Excavation Permit"
After the ' Sanitary Sewer Connection paragraph add the following
paragraphs:
Storm Sewer Connection. A utility exc avat ion. permit
Y-oran individual service connection shall be
obtained for any storm sewer service prior to
connecting, extending or reconstructing the service
to the structure or property to be served. The
permittee, at the permittee's expense, shall perform
all excavation, install an approved saddle on the
main, install all piping, place all backfill and
restore all surfaces. The City shall inspect the
connection and service prior to backfill. Require-
ments for restoration of paved surfaces shall be
the same as for the water tap.
Private Utility Taps and Connections. A utility
excavation permit for an individual tap or connection
to an underground private utility (gas, power, tele-
phone, etc.) shall be obtained prior to tapping or
connecting to said utility. The permittee shall
perform all excavation, place all backfill and
restore all surfaces. Requirements for restorations
of paved surfaces shall be the same as for the
water tap.
2. Public Right of Way Improvement Permit. All
work within the public Tight of way, that is not a
component of the utility excavation permit, shall
-require a public right of way improvement permit
approved by the Director of Public Works or his
authorized representative. The permit will not be
approved until all licensing, insurance and bonding
requirements have been met and necessary fees paid.
This permit shall include, but is not.limited to,
street construction, sidewalk and curbing install-
ation, driveway access, etc.
Page T-5 GP-10
Guarantee for Equipment, Materials, and Workmanship.
At the end of the paragraph add the following sentences:
Until the -record drawings (described in Section
II, Article DC-09) have been submitted to the City,
the City will not accept the job or the project as
completed. After the drawings have been submitted
to the City, the City will issue written acceptance
to the engineer. From the date of written acceptance
by the City the one year guarantee period begins.
Page 11-4
Storm Drainage Systems
Change the first sentence to read as follows:
For any development, irrespective of the number of
lots, containing 28,000 or more square feet, the
Professional Engineer shall submit a
Page 11-9
Drawing Submittal
In the first paragraph change "Construction Permit" to "Excava-
tion Permit"
In the third paragraph after the second sentence add the
following sentences:
The drawings shall define the typ'e and size of
pipe. They shall show the location of all underground
f ittings. Vertical distances shall be tied to a
bench mark approved by the City. The drawings
shall show the testing results. The drawings shall
be certified by a licensed engineer from the State
of Montana.
Page 111-3
Fittings
Remove the old description and add the following:
for copper service piping shall be either Mueller
110 compression connections or flared connections
equal and similar to Mueller H-15400. Fittings
for PE service tubing shall be either Mueller 110
compression connections or Mueller Instatite
connections.
Page 111-6
Trench Maintenance
change "Completion of Work" to "Acceptance by City"
Page 1.11-20 R-04
Excavation
In the first paragraph add the following words in front of
"Permit":
"Utility Excavation Permit or Public Right of Way".
New Standards
Add the attached new standard R-13 and SS-6A
Standard SD-3
Change Caird to Neenah 2112
Standard SD-4
11
Add to the beginning of the upper note the following sentences:
Manhole ring and cover Neenah R-1390 or R-1733
with a one inch pick -hole located off -center. The
cover shall be marked "SANITARY SEWER" or "STORM
DRATN" according to application.
Standard SS-1
In the upper note change the first sentence to read as
follows:
Manhole ring and cover Neenah R-1390 or R-1733
with a one inch pick -hole located off -center. The
cover shall be marked "SANITARY SEWER" or "STORM
DRAIN" according to application.
Standard SS-3
In the upper note add the following sentences:
Manhole ring and covey shall be Neenah R-1390 or
R-1733 or equal with a one inch pick -hole located
off -center. The cover shall be marked "SANITARY
SEWER" or "STORM DRAIN" according to application.
Standard W-1
Remove the old standard drawing and add the new drawing.
Standard W-2
Remove the old standard drawing and add the new drawing.
Standard W-3
Remove the old standard drawing and add the new drawing.
Standard W-4
Remove the old standard drawing and add the new drawing.
Standards R-7, R-8, R-9, and R-10
Add the following statement to the notes:
"The City may accept an alternate street design
from a professional engineer if the traffic loads
and soil analysis determine different requirements.
The final street design must be approved by the
Director -of Public Works or his representative."
Remove the application for construction in/to public facilities
and add the public right of way permit and utility excavation
permit.
Page 11-9
Bottom line
Change "from" to "by"
Page II-k
Purpbse of Design
Change waived by the City" to waiver by
the Director of Public Works or his representative."
TYPE
SUPPI
VARI
TYPE I eARRICADE
NOTE:
For diry
shown,
TYPE M BARRICADE
3* MINIMUM
A45
A 1� I I ro _61
M-7
6-
TA.ULE VI-1 Darricades—Characteristies
Type
TYPE 11 BARR[CADE O'l
PORTABLE FLASHER SUPPORT
11
II
IT
III
Width of Rail
1 8, min-12, max
8' min-12' max
8' min-12' max
Length of Rail
60-81
3' min—V max
3' min —variable
Tnax
Width of Stripes
6 in.
6 in.
6 in.
Height
3 ft. min
3 ft. min
5 ft. min
Type of Frame
Demountable or
Heavy "A" Frame
Light "A" Frame
Post or Skids
Flexibility
Essenti.villy
movable
Portable
Essentially
permanent
NOTE: Refer to section 1, article GP-08 Safety of "Kalispells Standards
And General Provisions For Design And Construction" and the "Manu
On Uniform Traffic Control Devicesit.
I I
It
I
I
I
Hub or bell of equal diameter
as service line.
1. Hub or bell of equal diameter and type of pipe which -will be used for
. the service line shall be used for the connection to the existing main.
2. Hub or bell must not protrude more than 1/4 inch into existing mains.
3. All connections to mains shall be watertight. A filet of grout shall
be applied around the diameter of the hub or bell to assure a water-
tight or leakproof connection.
4. This type of connection shall be approved by the City,prior to installation.
.5. This type of connection shall be used on mains of 15 inches or larger
diameter.
6. All construction phases of this type of connection shall be inspected
by the City of Kalispell's Public Works Department.
CONSTRUCT1011-1 STA,'MARDS STORM DRAIN & SANITARY SEWER
CITY OF KALISPELL I SERVICE CONNECTIONS ISS-6A
386